[8] Periodic Downloading and Test Transmission Options
ON = Periodic Downloading Enabled.
The system will automatically place a call to the
downloading computer at the time programmed in the
System Clock Times and at the interval, in days,
programmed in the System Times. A Downloading
Telephone Number must be programmed in the
Downloading Computer Telephone Number section.
OFF = Periodic Test Transmission Enabled.
The system will automatically call the Programmed
Maintenance Telephone Number(s) and transmit the Test
Reporting Code programmed in the Maintenance Alarms
Reporting Codes section at the time programmed in the
System Clock Times and at the interval, in days,
programmed in the System Times.
[50] After Alarm Reporting Code
Program using the same method as sections [05] to [15].
This code will be transmitted with or instead of an opening
code if an alarm occurred during the last armed state. ‘00’ or
‘FF’ in this section will disable the feature.
[51] 3rd System Option Code
[1] Bell During Auto-Arm Options
ON = Bell During Auto-Arm Disabled.
The bell or siren will not be activated during the 1-minute
Auto-Arm warning time.
OFF = Bell During Auto-Arm Enabled.
The bell or siren will sound a single squawk every 10
seconds during the 1-minute Auto-Arm warning time.
[2] Auto-Arm Cancellation Options
ON = Access Code Required to Cancel Auto-Arming.
An Access Code must be entered to cancel the Auto-
Arm sequence during the 1-minute Auto-Arm Warning
time.
OFF = Any Keypress will Cancel Auto-Arming.
Pressing any key during the 1-minute Auto-Arm Warning
time will cancel the Auto-Arming sequence.
[3] 2-minute Keypad Time-out Enabled / Disabled
ON = 2-minute Keypad Time-out Enabled.
If no keys are pressed for 2 minutes, all keypad lights will
be shut OFF.
NOTE: This feature must not be usedNOTE: This feature must not be used
NOTE: This feature must not be usedNOTE: This feature must not be used
NOTE: This feature must not be used
with LCD keypads or the Escort module.with LCD keypads or the Escort module.
with LCD keypads or the Escort module.with LCD keypads or the Escort module.
with LCD keypads or the Escort module.
OFF = No Keypad Time-out.
The keypad lights will remain ON at all times.
[4] [P] Key Keypad Sounder Options
ON = Keypad Silent for [P] Key.
When a [P] Key alarm is generated, the keypad sounder
will not beep to acknowledge the alarm.
OFF = Keypad Audible for [P] Key.
When a [P] Key alarm is generated, the keypad sounder
will beep 3 times to acknowledge the alarm.
[5] [F] Key Enabled / Disabled
ON = [F] Key Disabled.
The [F] Key will not sound an alarm when pressed.
OFF = [F] Key Enabled.
Pressing and holding the [F] Key for 2 seconds will
generate a Fire alarm; the bell or siren will sound with a
pulsing tone, and an alarm reporting code (if
programmed) will be transmitted.
[6] Quick-Exit Enabled / Disabled
ON = Quick-Exit Enabled.
With the system armed in the Home-Away mode, users
may enter the [
Q][0] Command to allow a single Delay
Zone to be activated so they may leave the premises.
Only one Delay Zone may be activated; any additional
activity on another Delay Zone will generate an alarm. If
the Delay zone is still open two minutes after the [
Q][0]
command is entered, the Entry Delay will be initiated.
OFF = Quick-Exit Disabled.
[7] Answering Machine Over-ride Timer Option
ON = Over-ride Timer set for 120 seconds.
When ON, the delay between the first and second calls
from the downloading computer may not exceed 120
seconds. Refer to section [47] Light 7 for information on
how to use the Answering Machine Over-ride function.
OFF = Over-ride Timer set for 60 seconds.
When OFF, the delay between the first and second calls
from the downloading computer may not exceed 60
seconds.
[8] Bell Shutdown Enabled / Disabled
ON = Bell Shutdown Enabled.
The BELL output will not be activated for zones that have
exceeded the limit of alarms set in the Swinger Shutdown
counter.
OFF = Bell Shutdown Disabled.
The BELL output will be activated for all alarms on all
zones, even after the Swinger Shutdown counter has
been exceeded. The BELL output will continue to be
activated for all alarms, even though the alarms will not
be reported once the Swinger Shutdown counter has
been exceeded.
[52] Delay Before Transmission
Program the same as section [22]. This section defines how
long in seconds a burglary zone will wait before transmitting
an alarm. The fire zone and 24 hour zones do not have a
delay. The time may be programmed from 00 to 99 seconds
where 00 means no delay. If the system is disarmed before
the delay in transmission expires, no transmission will take
place.