29000601 R2
PC3000
Notice of Software Release
PC3000 software version 7.7 has now been released.
Several new features have been added to reduce the possibility of user caused false
alarms. And also, additional features have been added to provide further support for the
LINKS 1000 and Escort.
These changes are outlined in the following programming sections.
[22] System Times Page 18
System Times now allow more than 4 minutes of Entry or Exit Delay. It provides
users additional time when circumstances warrant. The default setting of Exit Delay
is 120 seconds.
[28] Programmable Input and Output Options Page 20
2nd Digit Programmable Output
[C] PGM Squawk Output (for use with options in section [60]).
[49] 4th System Option Code Page 23
Fire Zone on Switched Aux Supply
- Prevents Fire Alarm Circuit Troubles if [Q][4] is used to reset sensors.
Escort Accepts Master Code Only
- Remote access through the Escort requires the Master Code.
[57] LINKS 1000 Preamble for 1st Telephone Number Page 24
[58] LINKS 1000 Preamble for 2nd Telephone Number Page 24
[59] LINKS 1000 Preamble for Downloading Telephone Number Page 24
The LINKS 1000 preambles are 4 digit numbers which are used for programming
area codes in cases where the LINKS 1000 must call long distance.
[60] 6th System Option Code Page 25
PGM Squawk on Exit Delay - The PGM Output will squawk for the Exit Delay.
PGM Squawk on Entry Delay - The PGM Output will squawk for the Entry Delay.
Audible Exit Fault - The user is warned that a delay zone was left open when the
exit delay expired.
Audible Exit Delay with Urgency - The keypad sounds a pulsing tone for the exit
delay and sounds a faster pulsing tone for the last 10 seconds.
Urgency on Entry Delay - The keypad pulses the steady entry delay tone for the
last 10 seconds.
Closing Confirmation - The keypad will sound a short series of beeps when the
closing code has been successfully transmitted.
Exit Delay Termination - The exit delay is cancelled when a standard delay zone
is restored.
NOTE: Downloading Software DLS-1 Version 5.3 must be used to upload/download the new PC3000
v7.7 software. Do not attempt to upload/download with the DLS-1 Version 5.2 or earlier software.