1
System Introduction
S E C T I O N 1
1.1 PC5015 Specifications
Flexible Zone Configuration:
• 8 fully programmable zones
• 38 access codes: 32 user, 1 system master, 2 partition master, 2 duress and 1 maintenance
• Expandable to 32 zones
• Keypads with zone inputs available (PC5508Z, PC5516Z, PC5532Z, LCD5500Z, LCD5501Z, LCD5501Z32)
• Hardwired expansion available using the PC5108 eight zone expansion module
• Wireless expansion available using the PC5132 wireless zone expansion module (up to 32 wireless zones)
• Normally Closed, Single EOL, or Double EOL zone supervision
• 33 zone types, 8 programmable zone options
• 2 partitions
Audible Alarm Output:
• 700mA supervised bell output (current limited at 3 amps), 12 V
DC
• Steady or pulsed output
EEPROM Memory:
• Will not lose programming or system status on complete AC and battery failure
Programmable Outputs:
• Up to 14 programmable voltage outputs, 26 programmable options
• One low current (50 mA) PGM output on main panel
• One high current (300 mA) PGM output on main panel
• Eight additional low current (50 mA) PGM outputs available using the PC5208 module
• Four high current (1 Amp) PGM outputs available using the PC5204 module
• 1 PC5204 output fully supervised for siren output
Powerful 1.5 Amp Regulated Power Supply:
• 550 mA auxiliary supply, 12 V
DC
• Positive temperature coefficient (PTC) components replace fuses
• Supervision for loss of AC power, low battery
• Internal clock locked to AC power frequency
Power Requirements:
• Transformer = 16.5 VAC, 40VA
• Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid
Remote Keypad Specifications:
• 12 different keypads available:
- LCD5501(Z) alphanumeric keypad - LCD5501Z (32-433) fixed LCD keypad
- PC5508 (Z) 8 zone LED keypad - PC5532(Z) 32 zone LED keypad
- PC5516 (Z) 16 zone LED keypad - LCD5500(Z) alphanumeric keypad
• Each keypad has 5 fully programmable function keys • Connect up to 8 keypads
• Four-wire (quad) connection to Keybus • Built-in piezoelectric buzzer
• “Z” version keypads have zone input
Digital Communicator Specifications:
• Supports all major formats including SIA and Contact ID and Residential Dial
• Split reporting of selected transmissions to each telephone number
• 3 programmable telephone numbers • 2 account numbers
• Supports GSM1000 cellular communication • DTMF and pulse dialing
• DPDT line seizure • Anti-jam feature
• Event-initiated personal paging
System Supervision Features
The PC5015 continuously monitors a number of possible trouble conditions including:
• AC power failure • Trouble by zone • Fire trouble
• Telephone line trouble • Low battery condition • Bell output trouble
• Loss of internal clock • AUX power supply fault • Tamper by zone
• Failure to communicate • Module fault (Supervisory or Tamper) • Camera troubles via DLM-4
• RF jamming detection