S Y S T E M I N T R O D U C T I O N
2
False Alarm Prevention Features
• Audible Exit Delay • Audible Exit Fault • Urgency on Entry Delay
• Quick Exit • Swinger Shutdown • Recent Closing Transmission
• Cross Zone Alarm • Burglary-verified Timer • Double Hit Timer
• Communication Delay • Rotating Keypress Buffer
Additional Features
• Auto-arm by partition at specified time each day of the week
• Keypad activated alarm output and communicator test
• Keypad lockout
• Audio capability using the PC5928 Audio Interface Module which allows local intercom and central station 2-way
listen-in.
• All modules connect to the system via a four-wire Keybus up to 1000’/305m from main panel
• Event buffer can be printed using PC5400 RS-232 serial interface module
• Supports the Escort5580 Voice Prompt Module with automation/lighting Control
• 256 event buffer, time and date stamped
• Upload/download capability
• Periodic DLS call-up
• Daylight Savings Time option
• Downlook support (DLM-4L v1.0 and PC5108L)
• Engineer reset
• Disarming via a wireless key/keyswitch
• Violated zones at end of Exit Delay cancels arming
• Remote reset
• Keypad buzzers follow alarms
• Bell trouble latching
• Bell delay timer
• Keypad buzzers and tamper/faults
• User Walk Test
1.2 Additional Devices
In addition to the information below, see the back cover for a DSC Module Compatibility table.
1.2.1 Keypads
A maximum of eight (8) keypads can be connected to the control panel and can be any combination of the
following listed. Different keypads (with function keys) can be used for 8-zone, 16-zone and 32-zone systems.
PC5508/PC5508Z PC5516 / PC5516Z PC5532 / PC5532Z LCD5500/LCD5500Z LCD5501Z(32-433)
8 zone LED keypad 16 zone LED keypad 32 zone LED keypad LCD keypad LCD keypad
1.2.2 PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number of zones on the
system. Up to 3 modules can be connected to increase the system zones to a
maximum of 32. (See PC5108
Installation Instructions Sheet.
)
1.2.3 PC5132/PC5132-433 Wireless Receiver Module and Devices
The PC5132 wireless receiver module can be used to connect up to 32 wireless
devices. All use standard AAA or AA alkaline or lithium batteries (see PC5132
Installation Manual
for details.)
Additional wireless devices are available:
WLS904NB Wireless Motion Detector
The wireless motion detector can be used with the PC5132 wireless receiver to include wireless space protection.
The unit comes with four AAA batteries
.
WLS904(P/L) Wireless Motion Detector
The wireless motion detector can be used with the PC5132 wireless receiver to provide any of four detection patterns
with high traffic shutdown and adjustible sensitivity. The unit comes with two lithium EL123AP batteries.
TM
Ready Armed Trouble
AM