Section
3:
Dealing
With
Alarms
and
Emergencies
If
you
return
to
the
premises
and
the
bell
or
siren
is
on
-
DO
NOT
ENTER.
Contact
local
authorities
from
a
nearby
safe
location.
Read
this
section
carefully
so
that
you
will
know
what
to
do
if
your
system
goes
into
alarm.
Your
installer
will
tell
you
if
fire
detection
equipment
has
been
installed
and
enabled
on
your
NOTE:
A
fire
alarm
always
has
priority
over
an
intrusion
(burglary)
alarm.
Fire
Alarms
A
pulsing
bell
or
siren
indicates
a
fire
alarm.
If
there
is
a
fire,
or
if
you
are
not
sure,
fol¬
low
your
evacuation
plan
immediately.
(See
"Fire
Escape
Planning"
on
page
22.)
If
remote
monitoring
is
enabled,
the
system
will
send
a
fire
message
to
the
central
station.
Your
installer
may
have
set
up
the
keypad
Fire
keys
and
other
fire
equipment
to
send
a
fire
alarm
message
to
the
central
station
as
soon
as
they
are
activated.
Your
installer
may
have
set
up
other
equipment
(e.g.,
smoke
detectors)
to
have
a
30
second
delay
before
sending
the
alarm
message
to
the
central
station.
Your
installer
will
inform
you
how
the
equipment
on
your
system
operates.
Equipment
that
has
been
set
up
with
a
30
second
delay
(e.g.,
smoke
detectors)
gives
you
time
to
correct
the
problem
before
a
false
alarm
is
sent
to
the
central
station.
Your
installer
may
have
implemented
an
auto-verify
fire
zone
for
your
smoke
detector(s).
Consult
your
installer
for
a
detailed
explanation
of
its
function,
purpose
and
use.
NOTE:
If
you
suspect
that
a
fire
message
has
been
transmitted,
but
there
is
no
fire
condition,
call
the
central
station
to
avoid
an
unnecessary
response.
If
there
is
no
fire
condition,
to
silence
the
fire
alarm:
1.
Press
®
within
30
seconds
of
the
beginning
of
the
alarm.
The
fire
alarm
will
sound
again
if
the
smoke
detector
is
not
reset
within
90
seconds.
2.
To
reset
the
smoke
detectors,
press
®
©©.
After
the
smoke
detector
has
been
reset,
if
it
still
detects
smoke
the
alarm
will
sound
again.
If
there
is
no
smoke,
the
system
will
return
to
normal.
3.
To
silence
the
fire
alarm
after
the
30
second
delay
has
expired,
enter
your
[access
code],
NOTE:
Your
installer
may
have
programmed
the
system
to
operate
differently
than
described
above.
Ask
your
installer
for
more
information
regarding
your
system's
operation.