21
[90] Other Options
RF Jamming Detection
[93] RF Jam Detect Zone
(Default = 00)
NOTE: For UL Listed installations, the RF Jam feature must be enabled - Section [804], subsection [90], Option
[7] OFF.
NOTE: For DD243 installations, the RF delinquency feature should be enabled - Section [804], subsection [90],
Option [5] OFF.
Default Option(s) Option ON Option OFF
NA EU
Off Off 1-2 For Future Use
On Off 3 Wall Tamper Disabled Wall Tamper Enabled
On Off 4 Case Tamper Disabled Case Tamper Enabled
On Off 5 RF Delinquency Disabled RF Delinquency Enabled
Off Off 6 For Future Use
On Off 7 RF Jam Detect Disabled RF Jam Detect Enabled
Off Off 8 Global Placement Test Individual Placement Test
l____l____l Select an unused zone that will be violated when a jamming signal is detected