10
CONTROL PANEL FUNCTIONS
DC Circuit Breaker
When the DC Circuit Breaker is in the “ON” position, the generator is able to supply power to
connected electronic devices. When the DC Circuit Breaker is in the “OFF” position, the
generator will no longer supply power. The DC Circuit Breaker automatically turns “OFF” when
connecting electronic devices to the generator that exceed the generator’s rated output. If the DC
Circuit Breaker turns off, reduce the load of connected electronic devices until the load is within
the specified rated output. To re-establish power, return the DC Circuit Breaker back to the “ON”
position,At the same time, the Reset switch needs to be reset.
CAUTION!
If the DC Circuit Breaker turns off again, stop using the generator immediately and consult our
dealers.
Engine ECO Control
When the Engine ECO switch is turned to the “ON” position, the economy control unit
automatically determines the. generator’s proper engine speed based on the connected
electronic load. This results in superior fuel economy and reduces noise.
When the ECO switch is turned to the “OFF” position, the engine runs at the rated speed
of 3000 r/min.
Note: The ECO switch must be turned to the “OFF” position when using electronic devices
that require a large starting
current, such as a compressor.
Parallel Outlets
Located on the right side of the panel, the generator’s Parallel Outlets enable a user to run
two D8600i generator’s simultaneously. This operation requires special cables. When
operating parallel generators, the rated output is 14.7Kw . For cables and instructions
consult a dealer for a PARALLEL OPERATION CABLE KIT.
Only connect this generator to another D8600i Standard Generator or D8600i Companion Generator
Only use brands approved parallel operation cable kit to connect generators
WARNING!
Never connect generators that are different models.