OPERATION
Grounding the Generator
To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel
Functions pg. 11.
Standard Atmospheric Conditions Ambient Temperature: 77ºF (25ºC)
Barometric Pressure: 100kPa
Relative Humidity: 30%
Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity, or altitude
are higher than standard atmospheric conditions, the generator’s output will be reduced. The load attached to the
generator must therefore be reduced.
How to Start Engine
Generator start- Recoil status (D8600i)
Place generator on a level surface. All electrical loads MUST be disconnected from generator.
Turn the knob switch to the Gasoline position.
Turn the battery switch to the ON position
First gently pull the handle until the cable is hung tight, and then pull
hard and quickly.
(Tip: When pulling the handle, the other hand should hold the
generator to prevent it from falling)
A. When the ambient temperature is lower than 0℃(
32°F), the heating time is 3 min.
B.
When the ambient temperature is higher than 0
, the heating time is 1 min.
C.
After running the above time, it is recommended that the energy saving
Fuel o
Gasoline