generator. Always check oil level before each operation.
Recommended Oil: SAE
10W-30 Oil Capacity: 1.1L
ASSEMBLY
NOTE: Check the engine oil level before each use or every 8 hours of operation.
l Turn the generator off and allow the engine to cool for at least five minutes.
l Place the generator on a level surface in a well-ventilated area.
l Remove the bolt.
l Remove the engine service cover.
l Clean the area around the oil dipstick.
For initial oil fill:
l Slowly unscrew and remove the oil dipstick.
l Using the funnel, slowly pour the supplied engine oil into the oil fill hole. Stop
frequently to make sure you do not overfill. NOTE: Your generator was
functionally tested in the factory and may contain minimum residual oil. Additional
oil is required to operate the unit. Do not overfill.
A - Oil dipstick
B - Safe operating range
A
B
14
Replace and tighten the oil dipstick.
Install the engine service cover and tighten the bolts
To check oil level:
Slowly unscrew and remove the oil dipstick.
Clean the dipstick and re-seat it inside the oil ill hole. Do not thread the dipstick.
Remove the dipstick and verify that the oil level is within safe operating range.
If the oil level is low, add recommended engine oil in-crementally and recheck until the level is
within the safe operating range.
Replace the oil dipstick and hand-tighten.
Install the engine service cover and tighten the bolts
.