18
Test
To test the system:
follow installation steps (see previous paragraphs) installing the test spray cans (containing water)
arm the control panel: Peperosso is unlocked
trigger an alarm (do not provoke the confirm detector connected to input IN3)
o if Peperosso is connected in Instantaneous mode, the nebulisation of spray (with water) starts
immediately
o if is connected in Driven mode, provoke the confirm detector connected to IN3: Peperosso
will nebulize the spray can (with water)
Verify the detection area of the confirm detector is properly covered and adjusted to avoid
false detections
at the end of test change the test spray can with the chili pepper spray cans (see the spray can
substitution paragraph)