VENT-FREE GAS FIREPLACE
INSERT
OWNER’S OPERATION AND
INSTALLATION MANUAL
MODEL FDF300R
SKU #170032
PFS
®
US
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
This insert can be used in the mantel and
replace systems CM300-1
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-855-607-6557, 8:00 am - 4:30 pm EST,
Monday through Friday or email info@factorybuysdirect.com

Questions and Answers

  • N
    nelsonheatherSep 13, 2025
    Why does my Duluth Forge Indoor Fireplace smell like gas when burning?
    • C
      chambersericSep 13, 2025
      If you notice a gas odor during combustion in your Duluth Forge Indoor Fireplace, there might be foreign matter between the control valve and burner, which would require disassembling the gas tubing to remove the matter. Alternatively, there could be a gas leak that needs to be located and corrected.
  • J
    Jeffery TaylorSep 12, 2025
    What to do if burners won't light on my Duluth Forge Indoor Fireplace?
    • C
      Christina FullerSep 12, 2025
      If the burner(s) of your Duluth Forge Indoor Fireplace does not light after the ODS/pilot is lit, the burner orifice might be clogged and needs cleaning or replacement. Another possibility is that the burner orifice diameter is too small, requiring replacement. It is also possible that the inlet gas pressure is too low.
  • P
    psanchezSep 12, 2025
    How to fix no spark at pilot light on Duluth Forge Indoor Fireplace?
    • L
      Lisa VincentSep 12, 2025
      If there is no spark at the ODS/pilot when the ignitor button is pressed on your Duluth Forge Indoor Fireplace, the ignitor electrode may be positioned incorrectly or broken, requiring replacement. Alternatively, the ignitor electrode might not be connected to the ignitor cable, in which case you should replace the ignitor cable. The ignitor cable could also be pinched or wet; free it if pinched, and keep it dry. If the ignitor cable is broken, replace it. A bad piezo ignitor or a low battery could also be the cause, requiring replacement of the piezo ignitor or the battery.
  • A
    Andrew DavisSep 10, 2025
    Why does my Duluth Forge Indoor Fireplace shut off while in use?
    • D
      Debra DelgadoSep 10, 2025
      If your Duluth Forge Indoor Fireplace shuts off during use while the ODS is operating, it could be due to a few reasons. First, ensure that enough fresh air is available by opening a window or door for ventilation. Another potential cause is low line pressure, in which case you should contact your local gas supplier. Lastly, the ODS/pilot might be partially clogged, requiring cleaning.
  • B
    Brad ValentineSep 8, 2025
    Why is there white powder residue forming around my Duluth Forge 170032 Indoor Fireplace?
    • T
      thomaszacharySep 8, 2025
      If you notice a white powder residue forming within the burner box or on adjacent walls or furniture when using your Duluth Forge Indoor Fireplace, it is likely due to vapors from furniture polish, wax, carpet cleaners, etc., turning into white powder residue when heated. Turn off the heater when using these products.
  • A
    anthonyloganAug 23, 2025
    Why does my Duluth Forge 170032 produce unwanted odors?
    • J
      Jeffrey AlvaradoAug 23, 2025
      If your Duluth Forge Indoor Fireplace produces unwanted odors, it could be due to several reasons. The heater might be burning vapors from paint, hair spray, or glues. Ventilate the room and stop using odor-causing products while the heater is running. Another cause could be a gas leak; in this case, you should locate and correct all leaks. Lastly, check if the fuel supply is low and refill the supply tank if needed (for Propane/LP models).
  • K
    kbraySep 6, 2025
    Why does my Duluth Forge 170032 Indoor Fireplace make a whistling noise?
    • N
      Nicholas WellsSep 6, 2025
      If your Duluth Forge Indoor Fireplace heater produces a whistling noise when the burner is lit, try turning the control knob to the low (1) position and let it warm up for a minute, especially if the burner is cold. The noise could also be due to air in the gas line; operate the burner until the air is removed from the line and have the gas line checked by your local gas supplier. Blocked air passageways on the heater can also cause this, so observe minimum installation clearances. Lastly, a dirty or partially clogged burner orifice can cause this, so clean or replace the burner orifice.
  • B
    Billy GonzalezSep 5, 2025
    Why is the flame yellow on my Duluth Forge Indoor Fireplace?
    • R
      robinsoncherylSep 5, 2025
      If your Duluth Forge Indoor Fireplace has a high yellow flame during burner combustion, it could be due to not enough air. Check the burner for dirt and debris and clean it if found. The gas regulator might be defective, so replace it. Also, the inlet gas pressure could be too low, so contact your local gas supplier.
  • R
    Ronnie MooreSep 4, 2025
    Why is there smoke or odor during the first use of my Duluth Forge 170032?
    • M
      Marissa PattersonSep 4, 2025
      If you notice a slight smoke or odor during the initial operation of your Duluth Forge Indoor Fireplace, it is likely due to residues from the manufacturing process. This problem should stop after a few hours of operation.
  • O
    Olivia OwenSep 3, 2025
    Why is there a delayed ignition of the burner(s) in my Duluth Forge 170032?
    • R
      Rhonda VaughnSep 3, 2025
      If your Duluth Forge Indoor Fireplace has a delayed ignition of burner(s), the manifold pressure might be too low, so contact your local gas supplier. Another possible cause is a clogged burner orifice, so clean the burner or replace the burner orifice.