Duluth Forge DF300L - Burner Inspection and Maintenance

Duluth Forge DF300L
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.factorybuysdirect.com
21200337-01A
Yellow
Tipping
INSPECTING BURNERS
IMPORTANT: Owners should check pilot ame pattern and burner ame pattern often.
Incorrect ame patterns indicate the need for cleaning (see Care and Maintenance,
page 22) or service.
WARNING: Only a qualied service person should service and
repair heater. This includes maintenance requiring replacement or
alteration of components.
PILOT FLAME PATTERN
Figure 23 - Correct Pilot Flame Pattern
Figure 24 - Incorrect Pilot Flame Pattern
Figure 25 - Correct Burner Flame Pattern
Figure 26 - Incorrect Burner Flame
Pattern
Figure 23 shows a correct pilot ame pattern.
Figure 24 shows an incorrect pilot ame pat-
tern. The incorrect pilot ame is not touching
the thermocouple. This will cause the ther-
mocouple to cool, which shuts the heater off.
If pilot ame pattern is incorrect, as shown
in Figure 24
turn heater off (see To Turn Off Gas to Ap-
pliance, page 19)
see Troubleshooting pages 23 through 26.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If the burner ame
pattern shows yellow tipping,
follow instructions at bottom of
this page.
Notice: Do not mistake orange ames with
yellow tipping. Dirt or other ne particles enter
the heater and burn causing brief patches of
orange ame.
BURNER FLAME PATTERN
Figure 25 shows a correct burner ame pat-
tern. Figure 26 shows an incorrect burner
ame pattern. The incorrect burner ame
pattern shows yellow tipping of the ame. It
also shows the ame higher than 1/2 the heat
shield height.
If burner ame pattern is incorrect as shown
in Figure 26:
turn heater off (see To Turn Off Gas to Ap-
pliance, page 19)
see Troubleshooting pages 23 through 26.
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC