Umgebungstemperatur
Ambient temperature
~(AC) 50 Hz 230 V -15 °C… +70 °C
~(AC) 50 Hz 110 V
~(AC) 60 Hz 120 V
~(AC) 60 Hz 220 V
~(AC) 50 Hz 240 V
~(DC) 24 V
Betriebs- und Montagean-
leitung
Ventilprüfsystem
Typ VPS 504
S01, S02, S03, S04, S05
Operation and assembly
instructions
Valve proving systems
Type VPS 504
S01, S02, S03, S04, S05
Druckabgrie
Pressure taps
Einbaulage
Installation position
1
Anschluß p
e
, p
1
Connection p
e
, p
1
2
Anschluß p
a
, p
2
Connectionp
a
, p
2
3,4
Meßstutzen
Measuring socket
Max. Betriebsdruck
Max. operating pressure
p
max.
= 500 mbar (50 kPa)
VPS 504 S01
VPS 504 S02
VPS 504 S03
VPS 504 S04
VPS 504 S05
nach / acc.
EN 1643
U
n
~(AC) 230 V-15 %…- 240 V+6 % 50 Hz
oder/or
~(AC) 110 V 50 Hz,
~(AC) 110/120 V 60 Hz,
~(AC) 220 V 60 Hz,
= (DC) 24 V
Einschaltdauer/Switch-on duration/ 100 %
Schutzart / Degree of protection
IP 40: VPS 504 S01, S02, S03
IP 54: VPS 504 S04, S05
nach / acc.
EN 60529
Familie 1 + 2 + 3
Family 1 + 2 + 3
1 + 2 + 3
}
-15°C…+60 °C
[ V ]
Seite 2 beachten!
see page 2!
Lagertemperatur
Storage temperature
储存温度
–15 °C … +80 °C
Question and Answer IconNeed help?

Do you have a question about the Dungs VPS 504 S04 and is the answer not in the manual?

Dungs VPS 504 S04 Specifications

General IconGeneral
BrandDungs
ModelVPS 504 S04
CategoryControl Unit
LanguageEnglish

Summary

Operation and Assembly Instructions

Valve Proving Systems Type VPS 504

Details the valve proving systems of type VPS 504.

Fields of Application

Mandatory Warning Instructions

Crucial safety warnings and precautions that must be observed.

Technical Data

Maximum Torque and System Accessories

Use Proper Tools

Emphasizes the importance of using the correct tools for installation.

Vibration-Free Installation

Instruction to ensure the equipment is installed without vibration.

Function of VPS 504

Test Procedure Based on Burner Sequence

Explains how testing depends on the burner's functional sequence.

Program Sequence Diagram

Valve Replacement for Leaks

Instructions on replacing valves if leaks are detected.

Mounting VPS 504

Turn Off Gas Supply

First step in mounting: disconnect the gas supply.

Switch Off Power Supply

Second step in mounting: disconnect the power supply.

Electrical Connection VPS 504 S01

Series Connection

Describes the series connection of VPS 504 S01 between regulator and control box.

Electrical Connection VPS 504 S01 SSM

Details the electrical connection for the VPS 504 S01 SSM variant.

Electrical Connection VPS 504 S02

Electrical Connection VPS 504 S04

Floating Signal Usage Warning

Warning about the use of floating control panel signals.

Test Volume for DUNGS Multi-Position Valves

Maximum Test Volume Limit

Warning that the maximum test volume of 4.0 I must not be exceeded.

Spare Parts and Accessories

Work by Specialist Staff Only

Operating Temperature Limit for LPG

Warning about operating the VPS 504 below 0 °C in liquid gas systems.

Motor Startup Current Consideration

Reminder to check motor startup current.

Safety Relevant Component Lifespan