INSTALLATION,
OPERATION &
MAINTENANCE
MANUAL
Form No: MM0422A
R134aR134aR134a
50/6050/60 Hz50/60
INSTALLATION,
OPERATION &
MAINTENANCE
MANUAL
Products That Perform . . .By People Who Care
®
MODEL:
WCFX Series
ROTARY
SCREW
WATER
CHILLERS

Table of Contents

Questions and Answers

  • M
    Michelle ReyesNov 3, 2025
    What to do if my Dunham-Bush WCFX 15 Chiller unit will not start?
    • M
      Michelle LewisNov 3, 2025
      If your Dunham-Bush Chiller won't start, there are several potential causes: * **Power Issues:** Verify that the main disconnect switch is on and the main line fuses are intact. * **Control Power:** Check the control transformer fusing. * **Compressor Circuit Breakers:** If the compressor circuit breakers are open, attempt to close them. If they trip again, inspect the compressor. * **Phase Control Relay:** If the phase control relay is open, check for power supply issues like low voltage or phase imbalance. Correct these issues and then press the reset button. * **Flow Switch:** Ensure pumps are running and check the flow switch. * **Compressor Switch:** Turn the compressor switch on and check the alarm status, correcting any problems. * **Microcomputer Shutdown:** Press t...

Summary

INSTALLATION AND START-UP PROCEDURES

REQUEST FOR START-UP REPRESENTATIVE

Procedure for scheduling and preparing for unit start-up.

CHILLER OPERATION AND CONTROL SYSTEMS

FREEZE PREVENTION GUIDELINES

Warnings and procedures to prevent freeze damage in various conditions.

ELECTRICAL SPECIFICATIONS AND CONTROLLER OPERATION

ADVANCED CONTROLLER FUNCTIONS

Details on compressor calibration, sensor calibration, and manual controls.

COMPRESSOR CONTROL AND SYSTEM FUNCTIONS

Manual compressor control and automated operational functions.

ADDITIONAL CONTROL FUNCTIONS

Details on interlocks, timers, load control, and other system functions.

PROTECTIVE CONTROL FUNCTIONS

Details on low/high pressure cut-offs, freeze shutoff, and electrical protections.

COMPRESSOR CALIBRATION AND SETTINGS

Procedures for calibrating compressor capacity and setting parameters.

MASTER;SLAVE CONTROL SEQUENCE

Sequencing multiple chillers for load demand.

MAINTENANCE AND TROUBLESHOOTING

TROUBLESHOOTING GUIDE

Common symptoms, possible causes, and remedies for unit issues.