Questions and Answers

  • E
    Eric BallardNov 2, 2025
    What to do if my Dunham-Bush WCFX 20 Chiller unit will not start?
    • M
      Monica EdwardsNov 2, 2025
      If your Dunham-Bush Chiller won't start, there are several potential causes: * **Power Issues:** Verify that the main disconnect switch is on and the main line fuses are intact. * **Control Power:** Check the control transformer fusing. * **Compressor Circuit Breakers:** If the compressor circuit breakers are open, attempt to close them. If they trip again, inspect the compressor. * **Phase Control Relay:** If the phase control relay is open, check for power supply issues like low voltage or phase imbalance. Correct these issues and then press the reset button. * **Flow Switch:** Ensure pumps are running and check the flow switch. * **Compressor Switch:** Turn the compressor switch on and check the alarm status, correcting any problems. * **Microcomputer Shutdown:** Press t...

Summary

Installation

Start-Up Representative Request

Procedure for scheduling and preparing for unit start-up.

Operation

Safety Relief Valves

Function and requirement of safety relief valves.

Freeze Prevention

Measures to prevent damage from freezing water in the unit.

Standby at Low Ambient Temperatures

Draining procedures for units in cold standby conditions.

Freeze Prevention In Operation

Freeze protection during normal operation.

Freeze Prevention During Maintenance

Freeze prevention during refrigerant transfer and maintenance.

Electrical

Vision 2020 i Controller Operation

Overview of the Vision 2020i controller, keypad, and functions.

Technician Functions and Calibration

Technician access, calibration of FLA/sensors, and manual control.

Control Functions

Detailed explanation of various safety and operational control functions.

Compressor Capacity Calibration

Procedure to calibrate compressor capacity based on FLA and load percentage.

Master;Slave Control Sequence

Sequencing multiple chillers for building load demand.

Hardware Settings

Configuring hardware settings for network addressing.

Controller Addressing

Setting DIP switches for controller DBLAN addresses.

Terminal Addressing

Setting terminal addresses for communication with controllers.

Maintenance

Water Side Cleaning

Detecting fouling and cleaning evaporator/condenser tubes.

Electrical Malfunction

Troubleshooting electrical issues like relay trips and overloads.

Charging

Procedures for refrigerant and oil charging.

Troubleshooting

Common symptoms, possible causes, and remedies for unit issues.

Dunham-Bush WCFX 20 Specifications