DUPLOMATIC E.M.DDC4-400V/RK RELEASE 1.9 07-09
EM DDC4-400-RK-0709gb.doc 8
I/O SIGNALS
OUTPUTS TO CNC (FROM I/O)
LOCKED: turret locked.
INDEXD: turret in position (can be used to start axis movement).
ALBIT1, ALBIT2, ALBIT4: alarms code.
OUTPUTS TO ELECTROVALVE (FROM I/O)
EVLOCK: locking valve.
EVULCK: unlocking valve.
INPUTS FROM CNC (TO I/O)
PBIT01, PBIT02, PBIT04, PBIT08, (PBIT16): position code bits.
PARITY: parity for position codes.
PSTART: signal for starting turret cycle.
MODE01, MODE02, MODE03: mode select code bits.
SPDSEL: selection of standard or maintenance speed.
INPUTS FROM TURRET (TO DRIVER)
LOCKSW: turret locked switch.
ULCKSW: turret unlocked switch (rotation free).
ZEROSW: turret reference switch (home switch).
MOTOVL: thermal detector switch of the motor (normally closed).
CONFIGURATION SELECTORS (TO I/O)
PTAB01, PTAB02: set 8/12 positions.
PTAB03: set low/high inertia.