DURASTAR.COM1
OWNER'S MANUAL
SLIM DUCTED INDOOR UNIT
SPLIT-STYLE AIR CONDITIONER
DRAD09F1A, DRAD12F1A, DRAD18F1A, DRAD24F1A
TIP
Capture relevant information about your Durastar mini-split equipment before it is
installed and write it above for future reference.
Model Number:
Serial Number:
Purchase Date:
Installing Contractor Company Name:

Other manuals for DURASTAR DRAD24F1A

Questions and Answers

  • I
    Isaac MyersSep 4, 2025
    What does it mean if my DURASTAR DRAD24F1A Air Conditioner displays low pressure protection?
    • A
      Amanda MooreSep 4, 2025
      If your DURASTAR Air Conditioner is showing a low pressure protection error, refer to service solution TS13-INV.
  • N
    Nicholas CastanedaSep 3, 2025
    What does it mean if my DURASTAR DRAD24F1A Air Conditioner displays IPM malfunction or IGBT over-strong current protection?
    • L
      laurahernandezSep 3, 2025
      If your DURASTAR Air Conditioner is experiencing IPM malfunction or IGBT over-strong current protection, refer to service solution TS09-L.
  • C
    Chad Baker MDSep 2, 2025
    What to do if DURASTAR DRAD24F1A displays over voltage or over low voltage protection?
    • D
      David AlexanderSep 3, 2025
      If your DURASTAR Air Conditioner is showing an over voltage or over low voltage protection error, refer to service solution TS10-L.
  • C
    cleeSep 1, 2025
    What to do if DURASTAR DRAD24F1A Air Conditioner displays current overload protection?
    • D
      Danielle BensonSep 1, 2025
      If your DURASTAR Air Conditioner is showing a current overload protection error, refer to service solution TS08-L- INV.
  • A
    Amanda AndersonAug 31, 2025
    What to do if my DURASTAR Air Conditioner doesn't respond to the remote control?
    • J
      John BerrySep 1, 2025
      If your DURASTAR Air Conditioner unit isn't responding to the remote control, the indoor PCB may need to be replaced.
  • B
    Brian DavidsonAug 31, 2025
    How to improve heating performance of my DURASTAR Air Conditioner?
    • N
      nguyenpatrickAug 31, 2025
      If your DURASTAR Air Conditioner's heating performance is poor, it could be due to extremely low outdoor temperatures; in this case, use an auxiliary heating device. Ensure that all doors and windows are closed to prevent cold air from entering. Also, low refrigerant levels due to leaks or long-term use can impact heating performance; check for leaks, re-seal if necessary, and top off the refrigerant.
  • E
    Evan WebbAug 30, 2025
    What to do if indicator lamps continue flashing or an error code appears on my DURASTAR Air Conditioner?
    • J
      jonesamandaAug 30, 2025
      Wait for about 10 minutes, as the problem may resolve itself. If not, disconnect the power, then connect it again, and turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center.
  • R
    Rebecca WebsterAug 29, 2025
    Why is my DURASTAR DRAD24F1A Air Conditioner's heating performance poor?
    • H
      Heather Ramirez MDAug 29, 2025
      Poor heating performance may occur if the outdoor temperature is extremely low; this model is designed to work down to -13°F, but heating performance is impacted below freezing. Also, ensure all doors and windows are closed to prevent cold air from entering. Low refrigerant levels due to leaks or long-term use can also cause this, so check for leaks, reseal if necessary, and top off the refrigerant.
  • M
    millermichaelAug 28, 2025
    Why does my DURASTAR Air Conditioner start and stop frequently?
    • C
      Chris OwenAug 28, 2025
      Frequent starting and stopping can be due to several reasons. There might be too much or too little refrigerant in the system, so check for leaks and recharge the system. Incompressible gas or moisture might have entered the system, requiring evacuation and recharge. The compressor could be broken and need replacement. Finally, the voltage might be too high or low, requiring a manostat to regulate it.
  • E
    Edward FordAug 27, 2025
    What to do if my DURASTAR DRAD24F1A Air Conditioner is not working?
    • K
      Krista HamiltonAug 27, 2025
      If your unit isn't working, first check for a power failure and wait for the power to be restored. Ensure the power is turned on. Replace the fuse if it's burned out. Replace the remote control batteries if they are dead. If the unit's 3-minute protection has been activated, wait three minutes after restarting it. Finally, check if the timer is activated and turn it off.

Summary

Warnings and Symbols

Important Safety Precautions

Operation, Cleaning, and Maintenance Safety

Safety guidelines for operating, cleaning, and maintaining the unit to prevent injury and damage.

Electrical Safety Guidelines

Installation Safety

Additional Safety Precautions

Precautions for using the unit, including power management and environmental factors.

Parts Identification

Operating Temperatures

Wired Thermostat Operation

Operating Modes

Heat Mode Operation

Advanced Features Overview

Care and Maintenance

Troubleshooting

Safety Precautions for Troubleshooting

Safety warnings for troubleshooting, advising to turn off the unit if certain conditions occur.

Troubleshooting Common Issues

Troubleshooting Problems and Solutions

Common Performance and Operational Issues

Addresses common issues like poor cooling/heating, frequent start/stop, and indicator lamps with causes and solutions.

Troubleshooting Unit Not Working

Error Codes Explained

Error Code Descriptions

Lists various error codes (E0-E5, EC, F0-F6, P0-P4, P6) and their corresponding error descriptions.

Limited Warranty - Parts

Warranty Information and Service

DURASTAR DRAD24F1A Specifications

General IconGeneral
Cooling Capacity24000 BTU/h
RefrigerantR410A
Noise Level (Outdoor Unit)55 dB(A)
TypeSplit System Air Conditioner
Power Supply220-240V, 50Hz
Operating Temperature Range (Cooling)18-43°C