5
ENG
* Advised pool volume for an entirely insulated pool, with cover, free from wind and exposed to the sun.
UNIT SUN12
Advised Pool volume* m
3
38
Operating air temperature °C 4 ~ 40
Air 27°C / Water 26°C / Humidity 80%
Heating Capacity kW 12,2
Btu 41628
Consumed power kW 2,068
COP 5,9
Air 15°C / Water 26°C / Humidity 70%
Heating Capacity kW 9
Btu 30709
Consumed power kW 1,837
COP 4,9
Power supply 230V / 50Hz / 1 Phase
Electronic Controller Colour LCD
Nominal Running current A 9
Max Current A 12
RCD - Rated current A 16 EU/SWISS & 13 UK
RCD - Leakage current mA 30
Condensor Titanium Heat Exchanger / NoFrost
Compressor quantity 1
Compressor type Rotary
Refrigerant R32
Refrigerant weight kg 0,95
Fan quantity 1
Fan power input W 80
Fan rotary speed RPM 1200
Fan direction Vertical
Noise at 10m dB(A) 44,7
Water connection mm 38
Water ow range m
3
/h 5 - 12
Unit net dimensions (L*W*H) mm See dimensions on p3
Unit shipping dimensions (L*W*H) mm 470x490x770
Net weight kg 45,7
Shipping weight kg 46,7