Owner's Guide
30
Part: XXXXX Rev XX
Model Name 26ECB5N 26ECB5L 26ECB6N 26ECB6L 21ECB5N 21ECB5L 21ECB6N 21ECB6L
Approval certification number SAI-400194
Type
Installation Outdoor, Wall Mounted
Air Supply/Exhaust Power Flue
Operating Pressure 200 -1,000 kPa
Minimum Flow Rate 2.5 L/min.
Dimensions 520mm (Height) x 350mm (Width) x 170mm (Depth)
Weight 18 kg 17 kg
Water Holding Capacity 0.9 L 0.8 L
Connection Sizes
Water Inlet R 3/4 (20mm)
Hot Water Outlet R 3/4 (20mm)
Gas Inlet R 3/4 (20mm)
Power Supply
Supply 230 - 240 VAC (50Hz)
Consumption
NG/LP : 49.0W/60.0W Freeze Prevention 130W NG/LP : 43.0W/52.0W Freeze Prevention 130W
Accessories Anchoring Screws
Item Maximum Performance
Gas
Consumption
NG 175 MJ/hr 145 MJ/hr
LP 185 MJ/hr 149 MJ/hr
Maximum Hot Water
Capacity
25°C Rise 26 L/min 21 L/min
Specifications
Performance
Specifications