ONYX DC FULL SERVICE19 ONYX DC FULL SERVICE
46.
45.
47.
Use the needle nose pliers to turn the low
speed needle all the way clock-wise. This is the
open position. Then you can push the bladder
unit all the way into the cartridge body.
Note: Oil will pour over the edge as you lower
the bladder unit into the cartridge.
Use the needle nose pliers to turn the low speed
needle all the way counter-clockwise. Then place
the bladder unit back into the cartridge body.
Push the bladder unit downward until you see the
oil level get to the top. Once you get to this point,
stop pushing down.
STOP WHEN
OIL REACHES
THE TOP