Operating and Maintenance Instructions
EN
LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR
8702037 – 01/01/2011 – R.0 www.dvp.it
15
6.3 SPARE PARTS
Use Original Spare Parts to replace pump parts.
When purchasing spare parts, always quote the serial number and model of the pump (these can be found on the
identification plate) as well as the spare part purchase number.
DESCRIPTION LB.5WR LC.25WR LB.40WR LB.60WR LC.105WR
Air exhaust filter kit
K9690029 K9690035 K9690031 K9690032 K9690034
Maintenance kit
K9690029/1 K9690035/1 K9690031/1 K9690032/1 K9690034/1
Oil 1 dm³
8832100 (SW60)
8812100 (BV68)
- - - -
Oil 2 dm³
8832200 (SW60)
8812200 (BV68)
- - - -
Oil 5 dm³
- - - -
8832500 (SW60)
8812500 (BV68)
8833500 (SW100)
8813500 (BV100)
Oil sight glass
- - - - 1105004
Oil viewer
5503002
Intake filter cartridge
1801019 - - - -
D.V.P. Vacuum Technology S.r.l. disclaims all responsibility for any deterioration of pump performance or for
damages caused due to use of non-original spare parts.
7 HOW TO RETURN THE PUMP
The product may only be returned after prior agreement with the supplier, who will provide the authorisation number
that must accompany the material delivered and should be duly complete in its entirety.
8 DISMANTLING
Demolition of the pump must be performed by authorised technicians.
Metal parts can be disposed of as scrap metal.
All materials deriving from demolition must be disposed of according to regulations in the country where the pump
will be demolished.
HAZARD
Disposal operations involve risks of cutting, shavings protection, entanglement, contact with
moving parts and contact with chemicals. Operators should use the appropriate personal
protective equipment.