3000 & 4000 Top Side Control Instructions
The system automatically performs two filter cycles per day, at 12-hour intervals. During a filter cycle:
• Pump 2 runs for one minute, then
• Pump 1 runs at low speed for the programmed number of hours
The "Filter Cycle" indicator lights up when the filter cycle is on.
To set the filter cycle duration:
Press and hold
Filter
key
until the display shows " xx ",
representing the currently
set filter cycle duration in
hours.
When the desired setting
is displayed, press Filter key
again to confirm. A filter cycle
starts immediately.
Use Up
or
Down arrow keys
to change setting.
0 = no filtration
12 = continuous filtration
13
Water temperature in the spa has reached 112º F (44º C).
Do not enter the water! Allow water to cool down. The
system will reset automatically when water temperature
reaches 109º F (43º C).
Call your dealer or service supplier if problem persists.
Water temperature is flashing.
The display is flashing.
GECKO
Pumps have started up for one
minute on several occasions and
"Filter Cycle" indicator is flashing.
3 flashing dots are displayed.
protects your spa from the
Not a bug but a feature!
Our
cold by automatically turning pumps on for one minute
several times a day to prevent water from freezing in
pipes.
A problem has been detected.
Do not enter the water! Check and open water valves.
Clean filter if necessary. Check water level. Add water
if necessary.
Shut power off and power your spa up again to reset the
system.
Call your dealer or service supplier if problem persists.
A power failure has occurred. Press any key to reset the
system, then reprogram all desired parameters.
Smart
Winter
Mode
104
An irregularly flashing "Filter" indicator light indicates that
the system has stopped filtering after 3 hours because the
water temperature exceeds the set point by more than
2º F (1º C). If the temperature cools down to 1º F (0.5º C)
above set point before the scheduled end of the cycle,
filtering will resume for the remainder of the programmed
duration.
Note: After a power failure, the filter cycle
duration will return to it's default value
(6 hours). In this case, the first filter cycle
will start 12 hours after power has been