EMS Operation
7-2 EMS-D10 Pilot’s User Guide
All screens in a DSAB network share a common dim level. Pressing BRITR or DARKR on one unit changes
the brightness level on all screens if the change is possible. If you have any D100-series bright screen units in
the system, you must press BRITR on any bright screen unit to get the bright screen units to their final step of
brightness.
The HS34 has a built-in light sensor which can be used to automatically dim all of the screens connected to a
DSAB network. To turn this function on, press AUTODIM. When you enable auto-dim, the screen does not
immediately change brightness. Instead, the system records the unit’s current brightness level as the desired
brightness. From that point on, all networked units react to changes in light intensity and maintain perceived
brightness at the desired level. If auto-dim is enabled and the screen is too bright or dark, continue to use the
BRITR or DARKR buttons as you would without auto-dim. The system records the new set level as the desired
brightness, and auto-adjusts around the new set point.
Fuel Computer
The fuel computer can be programmed in EMS > SETUP > FUEL > ADD THRESHOLD to automatically detect the
addition of fuel while the unit is turned off. When this is configured, the next time you turn the FlightDEK-D180 on, it
asks you if you added fuel and gives you a shortcut to the add fuel menu. See the EMS-D10 Installation Guide for more
information on configuring the fuel sensors and fuel computer.
Add Fuel: EMS > FUEL > ADD > INC+/DEC- > SEL► > ACCEPT/CANCEL
Use this to add to or subtract fuel from the EMS Fuel Computer. Press INC+ to add fuel. Press DEC- to subtract fuel.
Press SEL► to enter the value into the computer. Press ACCEPT to confirm the value. Press CANCEL if the value is
not correct. Note that you can also access the FUEL menu from the Auxiliary page, if you have the fuel computer info
item displayed on it.
Reset fuel level to pre-configured value: EMS > FUEL > PRESET