EMS Operation
7-6 EMS-D10 Pilot’s User Guide
Change power on alarms status: EMS > SETUP > GLOBAL > DOWN▼ > SEL► > BACK
Set this parameter to “ON” to enable alarms before engine startup. With this parameter set to “OFF”, all alarms are
suppressed whenever ALL of the following conditions exist:
• RPM less than 400
• Oil pressure less than 20 PSI
• First five minutes after master instrument power applied
All alarms are initialized when any of the above conditions are exceeded.
Test light/audio alarm(s): EMS > SETUP > GLOBAL > ALARM CONFIG > DOWN▼ > DOWN▼ > SEL►
Note: You must select an alarm to test using the UP▲/ DOWN▼ buttons. Hold SEL► to test the selected alarm.
Info Item Configuration: EMS > SETUP > GLOBAL > DOWN▼ >
DOWN▼ > DOWN▼ > SEL►
The INFO ITEM CONFIG submenu allows you to configure a variety
of different sensors as simple analog bars, on/off contacts, or text
items. Press the DOWN▼ button to select the item, INFO ITEM
CONFIG►. Press SEL► to enter the INFO ITEM CONFIG submenu.
The first two info items are displayed on the EMS Main Page. Info
item 1 is at the top right of the page, and info item 2 is at the lower
right of the page. The other six info items are located on the Aux Page
and are numbered 2 through 5 on the top row and 6 through 8 on the
bottom row.
The Info Items Config submenu appears, allowing you to move up and