EMS Operation
7-6 EMS-D10 Pilot’s User Guide
Change power on alarms status: EMS > SETUP > GLOBAL > DOWN > SEL > BACK
Set this parameter to “ON” to enable alarms before engine startup. With this parameter set to “OFF”, all alarms are
suppressed whenever ALL of the following conditions exist:
RPM less than 400
Oil pressure less than 20 PSI
First five minutes after master instrument power applied
All alarms are initialized when any of the above conditions are exceeded.
Test light/audio alarm(s): EMS > SETUP > GLOBAL > ALARM CONFIG > DOWN > DOWN > SEL
Note: You must select an alarm to test using the UP/ DOWN buttons. Hold SEL to test the selected alarm.
Info Item Configuration: EMS > SETUP > GLOBAL > DOWN >
DOWN > DOWN > SEL
The INFO ITEM CONFIG submenu allows you to configure a variety
of different sensors as simple analog bars, on/off contacts, or text
items. Press the DOWN button to select the item, INFO ITEM
CONFIG. Press SEL to enter the INFO ITEM CONFIG submenu.
The first two info items are displayed on the EMS Main Page. Info
item 1 is at the top right of the page, and info item 2 is at the lower
right of the page. The other six info items are located on the Aux Page
and are numbered 2 through 5 on the top row and 6 through 8 on the
bottom row.
The Info Items Config submenu appears, allowing you to move up and