Fitting notes
Service manual
47
122 Hold the switch cover in place
and test the buttons. The
brushbar button should work
independently from the On/Off
button. Pressing the On/Off
button when the brushbar button
is off should also activate the
brushbar button.
If this does not work
check the position of the
brushbar reset arm in the
triangular detail.
When working satisfactory fit the
three screws.
121 Locate the switch cover onto the front of the duct assembly. Ensure when fitting that the
brushbar reset arm locates into the triangular detail on the duct.
Triangular detail