- For the places where the appliance can be installed, the regulations stipulated by authorized gas
companies should be followed.
- If the appliance is installed in a cabinet, the distances required for maintenance and repair should
be at least as shown in Figure 3.
- Two air vents must be installed below and above the cabinet, the vents prevent the appliance from
heating by providing the ventilation of the cabinet. Areas of 110 cm2 for the cabinet vents directly
connected to the outside air, and 110 cm2 for the cabinet vents connected to the indoors must be
left. Since the outer surface temperature of your appliance does not exceed 85°C at maximum
heating power, special protective measures are not necessary against combustible building materials
and elements. By the authorized gas organizations, the following limitations have been set out for
the places where your room sealed appliance can be installed;
• The appliance must not be installed
In the stairwells of buildings,
• In the public use corridors of the buildings,
• On the chimney walls,
• In the light areas of the buildings.
Do not install your combi boiler in locations that will be exposed to direct sunlight. Sunlight can
cause color change on the outer surface of your appliance over time.
WARNING: The installaon locaon of the room sealed appli-
ance and the locaon of the room sealed flue outlet must
comply with the instrucons specified by the authorized gas
organizaons.
Figure 3
7
Determining Where to Install the Appliance
INSTALLATION