HOW to restore to the normal working status?
Open the door of the control cabinet and turn SA1 to OFF status;
PUSH DOWN I and DOWN II button to fully lower both lifting platforms;
Level until both platforms are synchronized. (Refer to step 6)
Turn SA1 to ON status.
SA1 Control “ON” or “OFF” for synchronization protection device
TROUBLE SHOOTING
ATTENTION: If the trouble could not be fixed by yourself, please do not hesitate to contact us for help .We will offer our service at the
earliest time we can. By the way, your troubles will be judged and solved much faster if you could provide us more details or pictures of
the trouble.
Motor does not run and
will not raise.
Check and make a good connection.
Damaged limit switch or its wire connection is loose.
Adjust or replace the limit switch.
Motor runs but will not
raise.
Check the wire connection.
Overflow valve is not well screwed up or jammed.
The hose connection is loose.
The cushion valve is not well screwed up or jammed.
Platforms go down
slowly after being
raised.
Untightened oil cylinder.
The single way valve leaks.
Solenoid valve fails to work well.
Check and adjust the tightness.
The overflow valve is not adjusted to the right position.
Too hot hydraulic oil ( above 45°).
Abraded seal of the cylinder