Installation, Operation and Parts Manual
EE62C-35T-E / EE62C-42T-E
Inspect if the valve leaks or not. Clean or change the valve if it leaks.
Check the synchronization of both carriages and adjust the tightness
of the cable if desynchronization is unacceptable.
Bushing of the upside pulley
and circlip of the shaft
Lubricate the bushing with NO.1 lithium based grease.
Check if the circlip is in its original position.
Lubricate the cables with NO.1 lithium based grease.
It is advised to change with new steel cables every 3 years or ten
single wires have broken.
Running track inside the
post for carriages
Lubricate the track with NO.1 lithium based grease.
No obstruction on the track.
Bushing of the downside
pulley and circlip of the
shaft
Lubricate the bushing with NO.1 lithium based grease.
Check if the circlip is in its original position.
Check with torque spanner.
For M18 bolt ,the torque is no less than 80N.m
Running the lift for several cycles with and without rated load. The
lift can run steadily and smoothly with no abnormal noise.
Bushing of the upside pulley
and circlip of the shaft
Slacken the steel cable and dismantle the pulley assembly. Measure
the abrasive clearance and change the bushing if the clearance is
bigger than 0.5mm.
Bushing of the downside
pulley and circlip of the
shaft
Slacken the steel cable and dismantle the pulley assembly .Measure
the abrasive clearance and change the bushing if the clearance is
bigger than 0.5mm.
Change the oil 6 months after initial use and once per year
thereafter. Inspect the hydraulic oil and change the oil if the oil
becomes black or there is dirt in the oil tank.
If users stick to the above maintenance requirements, the lift will always keep a good working
condition and its service life could be extended.