Hangzhou Zhongchuang Electronics Co., Ltd.
28
40kHz
100kHz
Inductance L and quality factor
100Hz/120Hz
40pF
0.00pF~39.99pF
2.5%+5 digits
------
Parallel
Range
Range of display
Accuracy Ce
Accuracy De
Equivalent
mode
recommended
100μF
40.00μF 100.00μF
6.00%+5 digits
0.0600
Series
40μF
4.000μF 39.999μF
4.0%+3 digits
0.0400
Series
4μF
400.0nF 3.9999μF
1.0%+2 digits
0.0100
Series
400nF
40.00nF 399.99nF
0.6%+2 digits
0.0060
Series
40nF
4.000nF 39.999nF
0.6%+2 digits
0.0060
------
4nF
400.0pF 3.9999nF
0.6%+2 digits
0.0060
Parallel
400pF
40.00pF~399.99pF
1%+3 digits
0.0100
Parallel
40pF
0.000pF~39.999pF
3%+5 digits
------
Parallel
Range
Range of display
Accuracy Ce
Accuracy De
Equivalent
mode
recommended
10μF
4.000μF 10.000μF
8.0%+20 digits
0.0800
Series
4μF
400.0nF 3.9999μF
5.0%+10 digits
0.050
Series
400nF
40.00nF 399.99nF
1.5%+5 digits
0.0150
Series
40nF
4.000nF 39.999nF
1%+2 digits
0.0100
Series
4nF
400.0pF 3.999nF
1%+2 digits
0.0100
------
400pF
40.00pF~399.99pF
1.5%+2 digits
0.0150
Parallel
40pF
4.000pF~39.999pF
2%+5 digits
0.0200
Parallel
4pF
0.000pF~3.999pF
5%+10 digits
------
Parallel
Range
Range of display
Accuracy Le
Accuracy
De*
Equivalent
mode
recommende
d
1000H
400.0H 999.9H
2.00%+3 digits
0.0200
Parallel
400H
40.000H 399.99H
0.60%+2 digits
0.0060
Parallel
40H
4.000H 39.999H
0.40%+2 digits
0.0040
Parallel
4H
400.0mH 3.9999H
0.40%+2 digits
0.0040
----
400mH
40.00mH 399.99mH
0.4%+2 digits
0.0040
Series
40mH
4.000mH 39.999mH
0.6%+3 digits
0.0060
Series