1-4-8. Enter this interface: main screen → parameter setting → next
page → next page.
1-4-9. Delay start time of wire release touch: It can change the sensitivity
of wire release trigger. The smaller the value is, the more sensitive it is.
1-4-10. Delayed start time for resetting the pay-off trigger: that is, after
the crimping is completed, the next trigger will take effect after the delay,
and the trigger will not be triggered again when the wire is taken slowly.
You can adjust this time according to the worker's wire take speed
Cooperate.
1-4-11. Main screen: Return to the main interface.