4
Instructions and Operation P52899
Effective July 2019
Box 1 and Box 2 non-combination enclosed
control and C600M cover control kit wiring
EATON www.eaton.com
Wiring diagrams: Lighting—electrically held, CN35
T1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
T1
T1
T1
T1
T1
T1
T1
T1
T1
T1
T1
T1T2 T2
T2
T2
CONNECTIONS FOR 2, 3, 4, 5, AND 6 POLE CONTACTOR CONFIGURATIONS
CN35A 10 AMP CN35B 20 AMP AND CN35G 60 AMP
2
POLE
3
POLE
4
POLE
5
POLE
CN35G
ONLY
6
POLE
CN35B
ONLY
2
POLE
3
POLE
4
POLE
2
POLE
3
POLE
4
POLE
5
POLE
6
POLE
CN35D 30 AMP
"C2"
"C2"
"C2"
"C2"
"C2"
"C2" "C2"
"C2"
"C2"
"C2"
"C2"
"C1"
"C1"
"C1"
"C2"
"C2"
"C1"
"C1"
"C1"
"C1"
"C1"
"C1"
"C1"
"C1"
"C1"
"C1"
L1
1
T1
2
L2
3
T2
4
L1
1
T1
2
L2
3
T2
4
L3
5
T3
6
L1
1
T1
2
L2
3
T2
4
L3
5
T3
6
L4
7
T4
8
L1
1
T1
2
T2
4
L2
3
L1
1
T1
2
T2
4
T3
6
L2
3
L3
5
L1
1
T1
2
L2
3
T2
4
L3
5
T3
6
L4
7
T4
8
L1
1
T1
2
T2
4
L2
3
L3
5
T3
6
T4
8
L4
7
L5
9
T5
10
L1
1
T1
2
T2
4
L2
3
L3
5
T3
6
L4
7
T4
8
T5
10
L5
9
L6
11
T6
12
L1
1
T1
2
L2
3
T2
4
L3
5
T3
6
L4
7
T4
8
L1
1
T1
2
L2
3
T2
4
L3
5
T3
6
L4
7
T4
8
L5
9
T5
10
L1
1
T1
2
T2
4
L2
3
L1
1
T1
2
T2
4
T3
6
L2
3
L3
5
L1
1
T1
2
T2
4
L2
3
L3
5
T3
6
L4
7
T4
8
T5
10
L5
9
L6
11
T6
12
M1
M1
M1
M1
M1
M1
M1
M1 M2
M2
M1 M2
M1
M1
M1
M1 M2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
1/L1
3/L2
CAUTION
READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE
CONTROL MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.
SEPARATE CONTROL POWER
FOR COIL VOLTAGES 120V AND LESS: CONNECT SEPARATE CONTROL LINES TO THE
NO. 61 TERMINAL ON THE TOP ADDER AUX. AND TO THE A2 TERMINAL ON THE COIL.
FOR COIL VOLTAGES GREATER THAN 120V: REMOVE WIRE "C2" IF SUPPLIED IF WIRE
"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT. SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE A2 TERMINAL ON THE COIL.
COMMON CONTROL POWER
FOR COIL VOLTAGES 120V AND LESS: ADD WIRE "C2" IF NOT SUPPLIED. ADD
CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 TERMINAL ON THE TOP ADDER
AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM.
FOR COIL VOLTAGES GREATER THAN 120V: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.
Wiring diagrams: Lighting—electrically held, C30CN
CAUTION
READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE
CONTROL MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.
SEPARATE CONTROL POWER
FOR COIL VOLTAGES 120V AND LESS: CONNECT SEPARATE CONTROL LINES TO THE
NO. 61 TERMINAL ON THE TOP ADDER AUX. AND TO THE A2 TERMINAL ON THE COIL.
FOR COIL VOLTAGES GREATER THAN 120V: REMOVE WIRE "C2" IF SUPPLIED IF WIRE
"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT. SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE A2 TERMINAL ON THE COIL.
COMMON CONTROL POWER
FOR COIL VOLTAGES 120V AND LESS: ADD WIRE "C2" IF NOT SUPPLIED. ADD
CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 TERMINAL ON THE TOP ADDER
AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM.
FOR COIL VOLTAGES GREATER THAN 120V: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.
R1
L1
CONNECTIONS FOR C30CN SERIES UPTO 12 POLE CONTACTOR CONFIGURATIONS
C30CNE ELECTRICALLY HELD
LINE
LOAD
VIEW A
COIL
VOLTAGE
OPTIONNAL
"NO"
AUXILIARY
CONTACTS
OPTIONNAL
"NC"
AUXILIARY
CONTACTS
"C1"
"C2"
1
A2
A1
M1
2
3
4
5
6
M1
3/L2
1/L1