ELC Programming Manual
FOR MORE INFORMATION VISIT: WWW.EATON.COM MN05003003E
2-114
Index Function
+3 Interval time of first segment (GT1)
+4 Interval frequency of first segment (GF1)
+5 Target frequency of first segment (TF1)
+6 Lower 16-bit of 32-bit of target number of first segment output pulse
+7 Upper 16-bit of 32-bit of target number of first segment output pulse
+8 Start frequency of second segment (SF2)
+9 Interval time of second segment (GT2)
+10 Interval frequency of second segment (GF2)
+11 Target frequency of second segment (TF2)
+12 Lower 16-bit of 32-bit of target number of second segment output pulse
+13 Upper 16-bit of 32-bit of target number of second segment output pulse
: :
+n*6+2 Start frequency of nth segment (SFn)
+n*6+3 Interval time of nth segment (GTn)
+n*6+4 Interval frequency of nth segment (GFn)
+n*6+5 Target frequency of nth segment (TFn)
+n*6+6 Lower 16-bit of 32-bit of target number of nth segment output pulse
+n*6+7 Upper 16-bit of 32-bit of target number of nth segment output pulse
Function Explanation:
This function can only be used for Y0 output point and the timing will be as follows. After filling
parameter table, set M1144 to start (it should be used in RUN mode)
SF2
TF2
SF3
TF3
TF4
SF4
TF1
SF1
GF
GT
GT
GF
Frequency(Hz)
Time(ms)
1st section
pulse number
(SE1)
2nd section
pulse number
(SE2)
3rd section
pulse number
(SE3)
4th section
pulse number
(SE4)
Usage rule and restriction: