ELC Programming Manual
FOR MORE INFORMATION VISIT: WWW.EATON.COM MN05003003E
2-126
b) Criteria for executing output shutdown: Shut down the criteria contact for pulse output
instruction and set M1335 as ON (Because PLSY does not have speeding up/slowing down
setting, M1335does not need to be set in PLSY)
c) The time from executing output shutdown to the end of pulse output: Max. 1 scan cycle.
Mode 3 – Immediate output shutdown
a) Applicable to: DDRVI, DDRVA, PLSY instructions
b) Criteria for executing immediate output shutdown: M1311 =ON (set before activating the
instruction) and the criteria triggers set in X11 (D1167=K0 refers to rising-edge; D1167=K1
refers to falling-edge)
c) The time from executing immediate output shutdown to the end of pulse output: Max. 1 pulse
time.
Note:
1. The execution criteria M1334 and M1335 of mode 1 and 2 have to be set before executing
pulse output shutdown instruction. The execution criteria M1310, M1311 and trigger criteria
D1166, D1167 of mode 3 have to be set before the pulse output instruction is activated.
2. In mode 3 (immediate output shutdown), Y10 can only be used with X10 and Y11 with X11.
3. When using X10 or X11 in mode 3, please do not use X10 or X11 as high-speed counter for
inputs.
Function Group
Right-Side Special Expansion Module ID
Number
D1320 ~ D1327
Contents:
1. The ID of special expansion module, if any, connected to ELCM-PH/PA are stored in D1320 ~
D1327 in sequence.
2. ID of each AIO module for ELCM-PH/PA:
Module Name Module ID (hex) Module Name Module ID (hex)
ELCM-AN04ANNN H’0080 ELCM-AN06AANN H’00C4
ELCM-AN02NANN H’0041 ELCM-PT04ANNN H’0082
ELCM-AN04NANN H’0081 ELCM-TC04ANNN H’0083
Function Group
Left-Side High-Speed Special Expansion Module ID
Number
D1386 ~ D1393
Contents:
1. The ID of left-side special expansion module, if any, connected to ELC-PV are stored in
D1386 ~ D1393 in sequence.
2. Left-side special expansion module ID for ELC-PV:
Module Name Module ID (hex)
ELC-CODNETM H’4131
ELC-COENETM H'4050