ELC Programming Manual
FOR MORE INFORMATION VISIT: WWW.EATON.COM MN05003003E
2-68
Special D
Function
ELC
-PB
ELCB
-PB
ELC
-PC
-PA
-PH
ELCM
-PH
- PA
ELC
-PV
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Type Latched
Factory
setting
ELC-PH: The 1
st
step start frequency
and the step end frequency of CH1
- Y - -
200 - - R/W NO
200
D1352
Start/end frequency of the 2
nd
group
pulse output CH1 (Y2, Y3)
- - Y Y 100
- - R/W
YES
(PV)
100
ELC-PH: Accelaration/Decelaration
time of CH1 pulse
- Y - -
200 - - R/W NO
200
D1353
Acceleration/deceleration time of the
2
nd
group pulse output CH1 (Y2, Y3)
- - Y Y 100
- - R/W
YES
(PV)
100
D1355
Starting reference for Master to read
from Slave ID#1
- Y Y Y 1064 - - R/W NO 1064
D1356
Starting reference for Master to read
from Slave ID#2
- Y Y Y 1064 - - R/W NO 1064
D1357
Starting reference for Master to read
from Slave ID#3
- Y Y Y 1064 - - R/W NO 1064
D1358
Starting reference for Master to read
from Slave ID#4
- Y Y Y 1064 - - R/W NO 1064
D1359
Starting reference for Master to read
from Slave ID#5
- Y Y Y 1064 - - R/W NO 1064
D1360
Starting reference for Master to read
from Slave ID#6
- Y Y Y 1064 - - R/W NO 1064
D1361
Starting reference for Master to read
from Slave ID#7
- Y Y Y 1064 - - R/W NO 1064
D1362
Starting reference for Master to read
from Slave ID#8
- Y Y Y 1064 - - R/W NO 1064
D1363
Starting reference for Master to read
from Slave ID#9
- Y Y Y 1064 - - R/W NO 1064
D1364
Starting reference for Master to read
from Slave ID#10
- Y Y Y 1064 - - R/W NO 1064
D1365
Starting reference for Master to read
from Slave ID#11
- Y Y Y 1064 - - R/W NO 1064
D1366
Starting reference for Master to read
from Slave ID#12
- Y Y Y 1064 - - R/W NO 1064
D1367
Starting reference for Master to read
from Slave ID#13
- Y Y Y 1064 - - R/W NO 1064
D1368
Starting reference for Master to read
from Slave ID#14
- Y Y Y 1064 - - R/W NO 1064
D1369
Starting reference for Master to read
from Slave ID#15
- Y Y Y 1064 - - R/W NO 1064
D1370
Starting reference for Master to read
from Slave ID#16
- Y Y Y 1064 - - R/W NO 1064
D1371
Time unit of PWM Y0 pulse output
when M1070=ON
- - - Y 1 - - R/W NO 1