Why is my Eaton UPS beeping continuously and the green button 12 flashing?
- JJoshua EllisAug 21, 2025
The UPS battery backup outlets 9 may be overloaded. Try reducing the load on these outlets.
Why is my Eaton UPS beeping continuously and the green button 12 flashing?
The UPS battery backup outlets 9 may be overloaded. Try reducing the load on these outlets.
What does it mean when the red LED 11 flashes on my Eaton Ellipse ECO 1200?
The battery has likely reached the end of its service life and needs to be replaced.
Why is my Eaton Ellipse ECO 1200 UPS beeping and the green button 12 flashing frequently?
The AC power source may be of poor quality. Consult the power supply specifications.
Why is the green button 12 flashing frequently and the audio alarm beeping on my Eaton Ellipse ECO 1200 UPS?
The green button 12 might be flashing frequently, and the audio alarm beeping because the Eaton UPS is frequently operating on battery power due to a poor-quality AC power source. To resolve this, have the electrical installation checked by a professional or try using another wall outlet.
What to do if green button 12 flashes and the audio alarm beeps continuously on my Eaton UPS?
If the green button 12 is flashing and the audio alarm is beeping continuously on your Eaton UPS, it indicates that the battery backup outlets 9 are overloaded. Disconnect some of the equipment connected to the battery backup outlets 9.
What does it mean if the red LED 11 is flashing on my Eaton Ellipse ECO 1200 UPS?
If the red LED 11 is flashing on your Eaton UPS, it means that the battery has reached the end of its service life. You should have the battery replaced.
What does it mean if the red LED 11 is on and the audio alarm beeps every 30 seconds on my Eaton Ellipse ECO 1200?
If the red LED 11 is on and the audio alarm beeps every 30 seconds on your Eaton UPS, it indicates a fault has occurred on the UPS and the battery backup outlets 9 are no longer supplied. Call after-sales support.
What to do if my Eaton UPS operates on battery power when AC power is available?
The circuit breaker 13, located under the UPS, may have been tripped by an overload on the UPS output. Try resetting the circuit breaker.
What to do if my Eaton Ellipse ECO 1200 UPS filtered outlets 8 are not supplied?
The wall outlet may not be supplied. Try resetting the circuit breaker.
What to do if EcoControl outlets keep powered when main application (Master outlet) is stopped in Eaton UPS?
The EcoControl function might not be activated or properly set. Activate or properly set the EcoControl function using the software provided with the product.
Output Voltage | 230V |
---|---|
Number of Outlets | 8 |
Output Voltage Regulation | ±10% |
Communication Ports | USB |
Input Frequency | 50/60 Hz |
Humidity | 0-95% non-condensing |
Topology | Line Interactive |
Battery Type | Sealed lead-acid |
Outlets Type | Schuko |
Data Line Protection | Internet |
Typical Backup Time at 70% Load | 6 minutes |
Output Power Capacity | 750W |
Output Frequency | 50/60 Hz |
Waveform Type | Stepped Sinewave |
Typical Recharge Time | 4-6 hours |
Communication Interface | USB |
Operating Temperature | 0-40°C |
Storage Temperature | -15-45°C |
Read safety instructions before installation and follow manual instructions.
Diagrams for FR/DIN, IEC, series, network, and USB connections.
Procedure for switching the UPS on using the ON/OFF button.
Instructions for registering the UPS warranty online.
Guidelines for safe battery disposal and handling.
Step-by-step guide for replacing batteries in Ellipse 500/650/800 and 1200/1600 models.
Connecting the UPS to AC power and peripherals, network, and USB.
Using EcoControl, threshold setup, UPS LEDs, buttons, and battery charging.
Adjusting UPS sensitivity to AC power variations for optimal performance.
Customizing audio alarm modes for UPS notifications.