R
Robert LiSep 7, 2025
What to do if the telephone line is disturbed when using Eaton UPS?
- SsotokristopherSep 7, 2025
Surge protection on the telephone line may no longer be provided. Check the modem connections.
What to do if the telephone line is disturbed when using Eaton UPS?
Surge protection on the telephone line may no longer be provided. Check the modem connections.
What to do if AC power is available, but my Eaton Ellipse ECO 1200 operates on battery power?
If your Eaton UPS is operating on battery power even when AC power is available, it could be due to circuit breaker 13, located under the UPS, having been tripped by an overload on the UPS output. Disconnect excess equipment and reset the circuit breaker 13 by pressing the corresponding button to resolve this issue.
What to do if the filtered outlets 8 are not supplied with power on my Eaton Ellipse ECO 1200?
If the filtered outlets 8 on your Eaton UPS are not supplied with power, there are two possible causes: 1. The wall outlet itself may not be supplied with power. Ensure the wall outlet has power. 2. Circuit breaker 13, located under the UPS, has been tripped by an overload on the UPS output. Disconnect excess equipment and reset the circuit breaker 13 by pressing the corresponding button.
Output Voltage | 230V |
---|---|
Number of Outlets | 8 |
Output Voltage Regulation | ±10% |
Communication Ports | USB |
Input Frequency | 50/60 Hz |
Humidity | 0-95% non-condensing |
Topology | Line Interactive |
Battery Type | Sealed lead-acid |
Outlets Type | Schuko |
Data Line Protection | Internet |
Typical Backup Time at 70% Load | 6 minutes |
Output Power Capacity | 750W |
Output Frequency | 50/60 Hz |
Waveform Type | Stepped Sinewave |
Typical Recharge Time | 4-6 hours |
Communication Interface | USB |
Operating Temperature | 0-40°C |
Storage Temperature | -15-45°C |
Read safety instructions before installation and follow manual instructions.
Diagrams for FR/DIN, IEC, series, network, and USB connections.
Procedure for switching the UPS on using the ON/OFF button.
Instructions for registering the UPS warranty online.
Guidelines for safe battery disposal and handling.
Step-by-step guide for replacing batteries in Ellipse 500/650/800 and 1200/1600 models.
Connecting the UPS to AC power and peripherals, network, and USB.
Using EcoControl, threshold setup, UPS LEDs, buttons, and battery charging.
Adjusting UPS sensitivity to AC power variations for optimal performance.
Customizing audio alarm modes for UPS notifications.