Service and Maintenance
Preventive Maintenance
Note: Item numbers refer to the illustration.
1. Air System and Connections
Check for leaks, worn air lines, loose connections and cap-
screws.
2. Clutch Housing Mounting
Check all capscrews of the clutch housing flange for looseness.
3. Clutch Release Bearing (Not Shown)
Remove hand hole cover and check radial and axial clearance in
release bearing.
Check relative positive of thrust surface of release bearing with
thrust sleeve on push-type clutches.
4. Clutch Pedal Shaft and Bores
Pry upward on shafts to check wear.
If excessive movement is found, remove clutch release mecha-
nism and check bushing on bores and wear on shafts.