M–2000–S
Revised 11–01–85
Vane Pumps
V100, V200, V300, V400
V500 and V2P Series
Overhaul Manual
Vickers
®
Vane Pumps

Questions and Answers

  • V
    Vincent ThomasAug 18, 2025
    What to do if my Eaton Vikers V2P Water Pump is making noise?
    • J
      Jackson PearsonAug 18, 2025
      If your Eaton Water Pump is making noise, the issue might stem from a few potential causes. Start by checking the intake strainers for blockage and assess the fluid condition, draining, flushing, and refilling the system with clean fluid if needed. Also, inspect the intake and shaft seal for air leaks, tightening any loose connections and replacing the seal if necessary, while ensuring the fluid level is adequate. Verify that the pump drive speed is within the recommended range. Lastly, examine the coupling for misalignment, replacing any damaged parts and realigning the coupled shafts.
  • M
    megan43Aug 29, 2025
    How to fix insufficient pressure build-up in my Eaton Water Pump?
    • C
      cynthia57Aug 29, 2025
      If your Eaton Water Pump isn't building up enough pressure, it could be due to the system relief valve being set too low; use a pressure gauge to adjust it correctly. Alternatively, worn parts might be causing internal leakage; in this case, replace the pump cartridge.
  • B
    Brenda RogersNov 8, 2025
    Why is my Eaton Vikers V2P Water Pump not delivering fluid?
    • D
      Derek JonesNov 8, 2025
      Several factors can cause an Eaton Water Pump to stop delivering fluid. It could be due to being driven in the wrong direction of rotation; change the drive direction immediately to prevent seizure, consulting the manual for the correct ring position for each direction. Other causes include a sheared or disengaged coupling or shaft (disassemble the pump and check for damage, replacing parts as needed), a restricted fluid intake pipe in the reservoir (check and clean strainers and filters), fluid viscosity being too heavy (drain the system and add new filtered fluid with the proper viscosity), air leaks at the intake causing priming issues (check inlet connections, tighten loose connections, ensure fluid level is above the intake pipe, and verify minimum drive speed), a relief valve stuck o...

Summary

Principles of Operation

A. Pumping Cartridge

Explains the working principle of the vane pump's pumping cartridge.

D. Flow Control and Relief Valve

Details how flow and pressure are regulated by valves in V200 pumps.

Installation and Operation

B. Drive Connections

Covers methods for connecting the pump shaft to the drive source.

E. Hydraulic Fluid Recommendations

Guides on selecting appropriate hydraulic fluids based on viscosity and additives.

F. Overload Protection

Discusses the role of relief valves in protecting the system from excessive pressure.

Service, Inspection & Maintenance

H. Troubleshooting

Lists common pump problems, probable causes, and remedies.

Overhaul Procedures

B. Disassembly

Details the step-by-step process for taking apart the vane pump.

C. Inspection and Repair

Outlines procedures for inspecting and repairing worn pump components.

D. Assembly

Describes the process of reassembling the vane pump after overhaul.

Pump Testing

Eaton Vikers V2P Series Specifications

General IconGeneral
CategoryWater Pump
Power SourceElectric Motor, Engine Driven
MaterialCast Iron, Bronze Fitted
ApplicationsIndustrial, Municipal, Agricultural
SeriesV2P Series