code
Request
0x1B
0
0.5 stop bit
1
1 stop bit
2
1.5 stop bit
3
2 stop bit
Response
0x1B
Same as request
For example,
Request
03 C0 1B 01
Response
03 40 1B 01
Remark
Restart takes effect, save after power off
5.4.1.24 UART stop bit acquisition
Operation
code
Parameter (1 byte)
Request
0x1C
N/A
Response
0x1C
Same as request
For example,
Request
02 C0 1C
Response
03 40 1C 01
Remark
5.4.1.25 Parity digit configuration
Operation code
Parameter (1 byte)
Request
0x1D
0
None parity
1
Even
2
Odd
Response
0x1D
Same as request
For example,
Request
03 C0 1D 00
Response
03 40 1D 00
Remark
Restart takes effect, save after power off
5.4.1.26 Parity digit acquisition
Operation
code
Parameter
Request
0x1E
N/A
Response
0x1E
Same as parity digit setting parameter
For example,
Request
02 C0 1E
Response
03 40 1E 00
Remark