EasyManua.ls Logo

Ebyte E104-BT11 - 5.4.1.24 UART Stop Bit Acquisition; 5.4.1.25 Parity Digit Configuration; 5.4.1.26 Parity Digit Acquisition

Ebyte E104-BT11
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT11 User Manual
Copyright ©2012–2020Chengdu Ebyte Electronic Technology Co.,Ltd
21
code
Request
0x1B
0
0.5 stop bit
1
1 stop bit
2
1.5 stop bit
3
2 stop bit
Response
0x1B
Same as request
For example,
Request
03 C0 1B 01
Response
03 40 1B 01
Remark
Restart takes effect, save after power off
5.4.1.24 UART stop bit acquisition
Operation
code
Parameter (1 byte)
Request
0x1C
N/A
Response
0x1C
Same as request
For example,
Request
02 C0 1C
Response
03 40 1C 01
Remark
5.4.1.25 Parity digit configuration
Operation code
Parameter (1 byte)
Request
0x1D
0
None parity
1
Even
2
Odd
Response
0x1D
Same as request
For example,
Request
03 C0 1D 00
Response
03 40 1D 00
Remark
Restart takes effect, save after power off
5.4.1.26 Parity digit acquisition
Operation
code
Parameter
Request
0x1E
N/A
Response
0x1E
Same as parity digit setting parameter
For example,
Request
02 C0 1E
Response
03 40 1E 00
Remark

Related product manuals