EasyManuals Logo

Ebyte E22-400T30D User Manual

Ebyte E22-400T30D
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Chengdu Ebyte Electronic Technology Co., Ltd. E22-400T30D User Manual
Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co.,Ltd.
15
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air data rate
(1.2K).
Send: C2 00 04 12 34 00 61
Return: C1 00 04 12 34 00 61
5
Wireless
configuration
Command: CF CF + normal command
RespondCF CF + normal respond
E.g 1: Channel is 0x09
Command head command starting address length parameter
Send: CF CF C0 05 01 09
Returen: CF CF C1 05 01 09
E.g 2: Configure module address (0x1234), network address (0x00), serial port (9600 8N1) and air data rate
(1.2K).
Send: CF CF C2 00 04 12 34 00 61
Return: CF CF C1 00 04 12 34 00 61
6
Wrong format
Wrong format respond: FF FF FF
7.2 Register description
Address
Read or
write
Name
Description
Remark
00H
Read/Wr
ite
ADDH
ADDHdefault 0
The module address is high byte and low byte. Note:
When the module address is FFFF, it can be used as
the broadcast and monitor address, that is the module
will not perform address filtering.
01H
Read/Wr
ite
ADDL
ADDLdefault 0
02H
Read/Wr
ite
NETID
NETIDdefault 0
Network address, used to distinguish the network.
When communicating with each other, they should
be set to the same.
03H
Read/Wr
ite
REG0
765 UART: Serial port ratebps
000: 1200
001: 2400
010: 4800
011: 9600default
100: 19200
101: 38400
110: 57600
111: 115200
---------------------------------------
43 Serial parity bit
008N1default
018O1
108E1
118N1equal to 00
-----------------------------------
210air data rate
000: 0.3k
001: 1.2k
010: 2.4kdefault
011: 4.8k
For the two modules that communicate with each
other, the serial port baud rate can be different, and
the verification method can also be different.
When transmitting large packets continuously, users
need to consider the data blocking caused by the
same baud rate, and data may even be lost. It is
generally recommended that both parties have the
same baud rate.
---------------------------------------
Both parties must be the same
The higher the rate, the shorter the distance