Loading...
Chengdu Ebyte Electronic Technology Co., Ltd. E22-400T30S User manual
Copyright ©2012–2018Chengdu Ebyte Electronic Technology Co.,Ltd.
17
0030dbmdefault
0127dbm
1024dbm
1121dbm
transmitting mode to read the register.
Register 0x00: Current ambient noise rssi
Register 0X01: rssi when the data was received last
time.
Current channel noise is: dBm =-RSSI/2
Command format: C0 C1 C2 C3 + starting address
+ read length
Returns: C1 + address + read length + read valid value
E.g: send C0 C1 C2 C3 00 01
Return C1 00 01 rssi
Address can only start from 00
----------------------------------
Power and current are nonlinear, and power
efficiency is highest at maximum power.
The current does not decrease in proportion to the
decrease in power.
05H
Read/W
rite
REG2
Channel controlCH
0-83 represents a total of 84 channels
Frequency= 410.125 + CH *1M
06H
Read/W
rite
REG3
7 Enable RSSI
1Enable
0Disabledefault
--------------------------------------
6 Fixed point transmission
1Fixed point transmission mode
0 Transparent transmission mode
default
---------------------------------------
5 Enable reply
1Enable repeater function
0Disable repeater function
--------------------------------------
4 LBT enable byte (monitor before
transmission)
1Enable
0Disabledefault
--------------------------------------
3 WOR transceiver control
1WOR transmitter
The module receiving and
transmitting functions are turned on, and a
wake-up code is added when transmitting
data. Receiving is turned on.
0WOR receiverdefault
The module is unable to transmit
data and works in WOR monitoring mode.
The monitoring period is as follows (WOR
cycle), which can save a lot of power.
---------------------------------------
210WOR cycle
000500ms
When enabled, the module receives wireless data
and it will follow an RSSI strength byte after
output via the serial port TXD
.---------------------------------------
The module recognizes the first three bytes of
the serial data as: address high + address low +
channel and takes it as the wireless transmitting
target.
---------------------------------------
After the reply function is enabled, if the target
address is not the module itself, the module will
forward it once.
In order to prevent data return-back, it is
recommended to use it in conjunction with the
fixed point mode. That is: the target address is
different from the source address.
----------------------------------------
When enabled, wireless data will be monitored
before it is transmitted, which can avoid
interference to a certain extent, but may cause
data delay.
----------------------------------------
Valid only for mode 1.
After the WOR receiver receives the wireless data
and outputs it through the serial port, it will wait
for 1000ms before entering the WOR again.
Users can input the serial port data and return it
via the wireless during this period. Each serial
byte will be refreshed for 1000ms. Users must
transmit the first byte within 1000ms.
---------------------------------------------
Valid only for mode 1.
Period T = (1 + WOR) * 500ms, maximum
4000ms, minimum 500ms
The longer the WOR monitoring interval period,
the lower the average power consumption, but

Related product manuals