Send: AT+ REGDATB1<cr>
Return: <cr><lf>+OK=< data,code ><cr><lf>
Set up the
Send: AT+ REGDATB1 =< data,code ><cr>
Returns: < CR > < LF > + OK < CR > < LF >
Parameters:
The registered package contents of ASCII code or hexadecimal data within 40 bytes of data.
Code ASCII or HEX
Example: AT+ REGDATB1=EBYTE, ASCII<cr>
7.4.20 AT+HRTDATA1: query/set serial port corresponding to SOCKET A1 heartbeat package content
Function: query/set serial port corresponding to SOCKET A1 heartbeat package content.
Format: query
Send: AT+ HRTDATA1 <cr>
Return: <cr><lf>+OK=< data,code ><cr><lf>
Set up the
Send: AT+ HRTDATA1 =< data,code ><cr>
Returns: < CR > < LF > + OK < CR > < LF >
Parameters:
The heartbeat packet contents of ASCII code or hexadecimal data within 40 bytes of data.
Code ASCII or HEX
Example: AT+ HRTDATA1= EBYTE,ASCII<cr>
7.4.21 AT+HRTDATB1: query/set serial port corresponding to SOCKET B1 heartbeat package content
Function: query/set serial port corresponding to SOCKET B1 heartbeat package content.
Format: query
Send: AT+ HRTDATB1 <cr>
Return: <cr><lf>+OK=< data,code ><cr><lf>
Set up the
Send: AT+ HRTDATB1 =< data,code ><cr>
Returns: < CR > < LF > + OK < CR > < LF >
Parameters:
The heartbeat packet contents of ASCII code or hexadecimal data within 40 bytes of data.
Code ASCII or HEX
Example: AT+ HRTDATB1= EBYTE,ASCII<cr>
7.4.22 AT+HRTMODA1: query/set the heartbeat packet mode of the serial port corresponding to SOCKET
A1
Function: query/set serial port corresponding to SOCKET A1 heartbeat packet mode.
Format: query
Send: AT+ HRTMODA1 <cr>
Return: <cr><lf>+OK=< mode ><cr><lf>