EasyManuals Logo

Ebyte NB144 User Manual

Ebyte NB144
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Chengdu Ebyte Electronic Technology Co., Ltd. NB144 User Manual
Copyright ©2012Chengdu Ebyte Electronic Technology Co., Ltd.
24
}
server address: ProductKey . iot-as-mqtt.cn-shanghai.aliyuncs.com:1883
pic for subscription and publishing : /a1GlhuTU1yN/DEV04/user/1234
Cloud MQTT platform communication test:
4.5 Channel port
random port:
TCP client, UDP client, HTTP client, MQTT client can configure the local port as 0 (use random local port),
server mode cannot use random port, otherwise the client cannot establish the connection correctly (device is not
correctly configured) port listening).
Using a random port connection can quickly re-establish the connection when the device is accidentally
disconnected from the server, preventing the server from rejecting the connection due to four waved incomplete. It
is recommended to use a random port in client mode.
When the device configures the TCP client, HTTP client, and MQTT client mode at AT , it will automatically
configure a random port, which can be canceled by customization.
Static port:
Device fixed port (factory default: 8 001-800 4 ), TCP server mode device listens to the configuration port,
accepts the connection request from the client and establishes a connection for data communication, and TCP client
mode device fixed port initiates a connection request.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ebyte NB144 and is the answer not in the manual?

Ebyte NB144 Specifications

General IconGeneral
BrandEbyte
ModelNB144
CategoryModem
LanguageEnglish

Related product manuals