Parameter 00 - 65 saved
LIST OF SERVICE PARAMETERS
Category
E2prom parameters
Unit
Range Default
Paramet Descrip�on Lower Upper Value
14 KW 20 KW 24 KW 28 KW 30 KW 35 KW
1=Instanta
neous
2=Instanta
neous +
Solar
Boiler
P00 DHW configura�on
3=Storage
Type tank
Num. 1 5 1 1 1 1 1 1
4 = Solar
storage
tank
5 = CH
only
System
P01
Gas type selec�on 0 = Natural
gas / 1 = LPG
Num.
0 1 0 0 0 0 0 0
System
P03
Water filling 1 = ac�ve / 0 =
inac�ve / 2 = automa�c
Num.
0 2 0 0 0 0 0 0
CH P26 CH off �me Min. 0 10 3 3 3 3 3 3
CH P35 OTC curve selec�on Num. 0 30 0 0 0 0 0 0
System
1 – Emas Hydroblock
(CCB Pakkens)
Configura�on
DHW P38 (Water Num. 1 2 1 1 1 1 1 1
pressure
2 - Bitron Hydroblock
circuit + flow
Figure 5
Then you can return to the previous menu by pressing the Reset button no 1 for 5 seconds and to the
main screen by pressing the Off button no 6.
You can access the following parameters on the Parameter Menu: “P00, P01, P03, P26, P35, P38,
P39, P40, P41, P44, P45, P46, P47, P48, P49, P50”