EasyManuals Logo

ECA CONFEO PREMIX P 24 HM Service Manual

Default Icon
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Parameter 00 - 65 saved
LIST OF SERVICE PARAMETERS
Category
E2prom parameters
Unit
Range Default
Paramet Descripon Lower Upper Value
14 KW 20 KW 24 KW 28 KW 30 KW 35 KW
1=Instanta
neous
2=Instanta
neous +
Solar
Boiler
P00 DHW conguraon
3=Storage
Type tank
Num. 1 5 1 1 1 1 1 1
4 = Solar
storage
tank
5 = CH
only
System
P01
Gas type selecon 0 = Natural
gas / 1 = LPG
Num.
0 1 0 0 0 0 0 0
System
P03
Water lling 1 = acve / 0 =
inacve / 2 = automac
Num.
0 2 0 0 0 0 0 0
CH P26 CH o me Min. 0 10 3 3 3 3 3 3
CH P35 OTC curve selecon Num. 0 30 0 0 0 0 0 0
System
1 Emas Hydroblock
(CCB Pakkens)
Conguraon
DHW P38 (Water Num. 1 2 1 1 1 1 1 1
pressure
2 - Bitron Hydroblock
circuit + ow
Figure 5
Then you can return to the previous menu by pressing the Reset button no 1 for 5 seconds and to the
main screen by pressing the Off button no 6.
You can access the following parameters on the Parameter Menu: “P00, P01, P03, P26, P35, P38,
P39, P40, P41, P44, P45, P46, P47, P48, P49, P50”
8

Other manuals for ECA CONFEO PREMIX P 24 HM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ECA CONFEO PREMIX P 24 HM and is the answer not in the manual?

ECA CONFEO PREMIX P 24 HM Specifications

General IconGeneral
BrandECA
ModelCONFEO PREMIX P 24 HM
CategoryBoiler
LanguageEnglish

Related product manuals