29
STORAGE
Storage
PREPARATION FOR STORAGE
The following procedures should be followed prior to storage of your
generator for periods of 6 months or longer.
1. Drain fuel from fuel tank carefully by disconnecting the fuel line.
Gasoline left in the fuel tank will eventually deteriorate making
2. Remove the drain screw of the carburetor.
3. Change engine oil.
4. Check for loose bolts and screws, tighten them if necessary.
5. Clean generator thoroughly with clean cloth. NEVER USE WATER
TO CLEAN GENERATOR.
6. Pull recoil starter handle until resistance is felt, leaving handle in
that position.
7. Store generator in a well ventilated, low humidity area.
Generator Specications
Engine Model R420D-V
Start Manual/Electric
Rated Frequency 60Hz
Rated Voltage 120V/240V
Rated Power 7.5KW
DC Output 12V, 8.3A
Fuel Tank Capacity 25L
Full Load Continuum Running Time 6h
50% Load Continuum Running Time 8h
Noise (7m) 84dB
2 x GFCI Duplex with water
proof cover, 1 x 120V- 30A
Twist lock-3prongs with
water proof cover, 1 x
120/240V- 30A Twist lock-4
prongs with water proof
cover, 3 in 1 digital meter,
Auto idle switch, Cigarette
lighter
CSA/EPA/CARB
LOW THD
Yes
Wheels & Kits
Yes