43
IN_VOL
<Input=I1:I5>
<Volume=0:99>
Sets the current VOLUME for the specified INPUT (general input
volume, affecting all the post processing)
IN_BASS
<Input=I1:I5>
<Gain=dBx10>
Sets the current BASS tone LEVEL for the specified INPUT
IN_MID
<Input=I1:I5>
<Gain=dBx10>
Sets the current MIDDLE tone LEVEL for the specified INPUT
IN_TREBLE
<Input=I1:I5>
<Gain=dBx10>
Sets the current TREBLE tone LEVEL for the specified INPUT
HPF_ACTIVE
<Input=I4:I5>
ON/OFF
Sets the current HIGH PASS FILTER status (ON or OFF) for the specified
INPUT
HPF_FREQUENCY
<Input=I4:I5>
<Frequency=Hz>
Sets the current HIGH PASS FILTER frequency (Hz) for the specified
INPUT
FBS_ACTIVE
<Input=I4:I5>
ON/OFF
Sets the current FEEDBACK SUPPRESSOR feature status (ON or OFF)
for the specified INPUT
GATE_ACTIVE
<Input=I4:I5>
ON/OFF
Sets the current NOISE GATE status (ON or OFF) for the specified
INPUT
GATE_THRESHOLD
<Input=I4:I5>
<Threshold=dBx10>
Sets the current NOISE GATE THRESHOLD LEVEL (dBx10) for the
specified INPUT
GATE_DEPTH
<Input=I4:I5>
<Depth=dBx10>
Sets the current NOISE GATE DEPTH (attenuation when gate is closed,
dBx10) for the specified INPUT
GATE_ATTACK
<Input=I4:I5>
<AttackTime=msx10>
Sets the current NOISE GATE ATTACK TIME (milliseconds x10) for the
specified INPUT
GATE_HOLD
<Input=I4:I5>
<HoldTime=msx10>
Sets the current NOISE GATE HOLD TIME (milliseconds x10) for the
specified INPUT
GATE_RELEASE
<Input=I4:I5>
<ReleaseTime=msx10
>
Sets the current NOISE GATE RELEASE TIME (milliseconds x10) for the
specified INPUT
TALKOVER_ACTIVE
<Input=I4:I5>
ON/OFF
Sets the current TALKOVER status (ON or OFF) for the specified INPUT
TALKOVER_MODE
<Input=I4:I5>
PAGER/DUCKER
Sets the TALKOVER function working mode (PAGER or DUCKER) for
the specified INPUT
TALKOVER_PRIORITY
<Input=I4:I5>
LOW/HIGH
Sets the current TALKOVER PRIORITY level (LOW or HIGH) for the
specified INPUT
TALKOVER_ZONES
<Input=I4:I5>
<Zones=ZA:ZD>
Sets the current TALKOVER assignment to outputs (ZONES) for the
specified INPUT. Zones parameter can include ZA to ZD, separated by
comma characters and no blank space (example: ZA,ZC,ZD)