EasyManua.ls Logo

Ecler CA120 - Page 61

Ecler CA120
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
XOVER_TYPE
<Zone=ZA:ZD>
LP/HP
Shows the current CROSSOVER FILTER TYPE (LP or HP) for the
specified output zone
XOVER_FREQUENCY
<Zone=ZA:ZD>
<Frequency=Hz>
Shows the current CROSSOVER FILTER FREQUENCY (Hz) for the
specified output zone
COMPRESSOR_ACTIVE
<Zone=ZA:ZD>
ON/OFF
Shows the current COMPRESSOR status (ON or OFF) for the specified
output zone
COMPRESSOR_THRESHO
LD
<Zone=ZA:ZD>
<Threshold=dBx10>
Shows the current COMPRESSOR THRESHOLD LEVEL (dBx10) for
the specified output zone
COMPRESSOR_RATIO
<Zone=ZA:ZD>
<Ratio=x100>
Shows the current COMPRESSOR RATIO (x100) for the specified
output zone
COMPRESSOR_ATTACK
<Zone=ZA:ZD>
<AttackTime=msx10>
Shows the current COMPRESSOR ATTACK TIME (milliseconds x10)
for the specified output zone
COMPRESSOR_RELEASE
<Zone=ZA:ZD>
<ReleaseTime=msx10>
Shows the current COMPRESSOR RELEASE TIME (milliseconds x10)
for the specified output zone
COMPRESSOR_KNEE
<Zone=ZA:ZD>
SOFT/HARD
Shows the current COMPRESSOR KNEE mode (SOFT or HARD) for
the specified output zone
COMPRESSOR_GAIN
<Zone=ZA:ZD>
<Gain=dBx10>
Shows the current COMPRESSOR GAIN (dBx10) for the specified
output zone
DELAY_ACTIVE
<Zone=ZA:ZD>
ON/OFF
Shows the current DELAY status (ON or OFF) for the specified output
zone
DELAY_TIME
<Zone=ZA:ZD>
<DelayTime=msx10>
Shows the current DELAY TIME (milliseconds x10) for the specified
output zone

Other manuals for Ecler CA120