EasyManua.ls Logo

Ecoflam MAX 30 - User Manual

Ecoflam MAX 30
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Technical data
Dati tecnici
Données techniques
Datos técnicos
Технические характеристики
Operating instructions
Istruzioni per l’uso
Notice d’emploi
Manual de uso
Руководство по эксплуатации
Electric and hydraulic diagrams
Schemi elettrico e idraulico
Schémas électrique et hydraulique
Esquemas eléctrico e hidráulico
Электрические и гидравлические схемы
Spare parts list
Pièces de rechange
Parti ricambi
Запчасти
Piezas de recambio
www.ecoflam-burners.com
LIGHT OIL BURNERS
EN
IT
FR
ES
RU
MAX 15
MAX 20
MAX 30
MAX 15 TC
3142729
MAX 15 TL
3142730
MAX 20 TC
3142731
MAX 20 TL
3142732
MAX 30 TC
3142733
MAX 30 TL
3142734

Other manuals for Ecoflam MAX 30

Questions and Answers

  • J
    Jose ChambersAug 9, 2025
    What to do if Ecoflam MAX 30 Burner starts and then shuts down after solenoid valves open?
    • J
      Julie EdwardsAug 9, 2025
      If your Ecoflam Burner starts but shuts down after the solenoid valves open, it indicates no flame signal at the end of the safety time. First, ensure the oil level in the tank is adequate and the valves are open. Then, examine the oil pressure, pump operation, coupling, filter, and solenoid valve. Next, check the ignition circuit and electrode adjustment, cleaning or replacing electrodes as necessary. Finally, clean or replace the flame monitor. If problems persist, consider replacing ignition electrodes, ignition cables, the ignition transformer, nozzle, pump, solenoid valve, or the automatic combustion control unit as needed.
  • E
    Elizabeth BrockAug 14, 2025
    Why Ecoflam MAX 30 does not start after thermostat shutdown?
    • C
      Carly WrightAug 14, 2025
      If your Ecoflam Burner doesn't start after the thermostat shuts down and there's no malfunction indicated on the automatic combustion control unit, it could be due to a drop in supply voltage, a power failure, or a control unit malfunction. You should check for the cause of the voltage drop or power failure. If those aren't the issue, replace the control unit.
  • R
    Russell ThomasAug 20, 2025
    What to do if Ecoflam Burner starts and shuts down after preventilation?
    • C
      Carolyn MartinezAug 20, 2025
      If your Ecoflam Burner starts and then shuts down after pre-ventilation, it may be due to flaring during pre-ventilation or pre-ignition. Check the ignition sparks and adjust or replace the electrode. Also, inspect and consider replacing the fuel-oil solenoid valve.
  • D
    David ParkerAug 27, 2025
    How to fix no heat request in Ecoflam Burner?
    • U
      ubrockAug 27, 2025
      If there is no heat request in your Ecoflam Burner, it means the thermostats are either defective or incorrectly adjusted. To resolve this, adjust the thermostats or replace them if necessary.
  • M
    Martin SalinasSep 2, 2025
    What to do if Ecoflam Burner starts briefly and shuts down with red LED on?
    • A
      Alexander PhillipsSep 2, 2025
      If your Ecoflam Burner starts briefly when switched on, then shuts down and the red LED lights up, it indicates that the control unit has been intentionally locked. To resolve this, reset the control unit.

Summary

Ecoflam Light Oil Burner Overview

Technical Data

Introduces the detailed specifications and performance data for the burners.

Operating Instructions

Introduces guidelines for the proper installation and operation of the burner.

Detailed Technical Data

Burner Performance Specifications

Provides detailed technical specifications for MAX 15, MAX 20, and MAX 30 burners.

Burner Functionality and Safety

Operating Function Sequence

Describes the burner's operational sequence from request to start.

Safety Shutdown Conditions

Explains safety shutdown triggers and malfunction indicators.

E-BCU Control Unit Operation

E-BCU OIL Control Unit Function

Details the microprocessor-controlled unit that monitors and controls the burner.

Start-Up Settings and Adjustment

Setting Data Table for Air Regulation

Recommended settings for nozzle, firing head, and air damper.

Start-Up: Output and Pressure Regulation

Adjusting Burner Output via Oil Pressure

How to set burner output by regulating oil pressure.

Service and Maintenance

Troubleshooting and Faults

Fault Diagnosis and Remedies

Steps to diagnose malfunctions and apply corrective actions.

Common Faults and Solutions Table

A reference table listing faults, causes, and recommended repairs.

Ecoflam MAX 30 Specifications

General IconGeneral
BrandEcoflam
ModelMAX 30
CategoryBurner
LanguageEnglish

Related product manuals