Specification ecoGEO B/C 5-22
Geothermal / Aerothermic / Hybrid
HTR - High temperature recovery system
Integrated active cooling
Passive outdoor cooling control
Compressor range of modulation
Active cooling power
2
, B35W7
Maximum unassisted DHW temperature
Maximum assisted DHW temperature
5
Energy label / ηs with average temperature control
Heating outlet temperatura range
10 to 60 (Max setpoint 60°C)
Cooling outlet temperatura range
4 to 35 (Min setpoint 7°C)
Brine inlet temperature in heating mode range
Brine outlet temperature in cooling mode range
Cooling circuit pressure min / max
Production / Pre-load circuit pressure
Brine / Pre-load circuit pressure
Maximum DHW storage tank pressure
Compressor oil type / load
Maximum recommended external protection
9
Transformer primary circuit fuse
Transformer secondary circuit fuse
Electrical data:
Single phase
Maximum recommended external protection
9
Maximum consumption
2
, B0W35
Maximum consumption
2
, B0W55
Starting current min/max
7
Electrical data:
Three phase
Maximum recommended external protection
9
Maximum consumption
2
, B0W35
Maximum consumption
2
, B0W55
Starting current min/max
7
ecoGEO B: 1060x600x710
ecoGEO C: 1804x600x710
Empty weight (without assembly)
1. Replacing or combining the geothermal collector with one or more ecoGEO AU12 aerothermal units. Refer to the ecoGEO AU12 aerothermal
units manual for more detailed information.
2. In compliance with EN 14511, this includes the consumption of the circulation pumps and the compressor driver.
3. Considering brine and production flows of 2500 l/h.
4. Considering a heat ramp of 20°C to 50°C in absence of consumption.
5. Considering support provided by the emergency electrical resistor or the HTR system. Maximum DHW temperature with the HTR system can
be limited by the compressor discharge temperature.
6. In compliance with EN 12102, this includes the acoustic insulation kit of the compressor.
7. Starting current depends on working condition of the hydraulic circuits.
8. The admissible voltage range for proper operation of the heat pump is ±10%.
9. Maximum consumption can vary significantly according to working conditions, or if the compressor's range of operation is restricted. Refer
to the technical service manual for more detailed information.