Questions and Answers

  • J
    Jacqueline PowersAug 11, 2025
    What to do if the red LED flashes on my Ecolab Ecodos-PCB?
    • J
      Jon HenryAug 12, 2025
      If the red LED is flashing, it could indicate a low-level detection or that no capsule is inserted. Replace the container or insert a capsule to resolve the issue.
  • M
    Matthew HernandezAug 17, 2025
    What to do if the red LED is permanently on in inductive mode on my Ecolab Computer Hardware?
    • B
      Brenda HowellAug 17, 2025
      If the red LED is permanently on in inductive mode, the measuring probe may not be connected or may be defective, or the max dosage time may be exceeded. Connect the inductive probe, replace it if defective, and check the container/capsule, pump functionality, and solenoid valve/water supply.
  • R
    royjohnAug 23, 2025
    How to fix Ecolab Ecodos-PCB Computer Hardware when the LED does not illuminate after applying power from the dishwasher?
    • A
      Adam WiseAug 23, 2025
      If the LED does not illuminate when power is applied, it could be due to a defective transformer or wiring, or a defective PCB. Check the transformer and wiring, and replace if required. If that's not the case, replace the PCB.
  • M
    michaelmartinAug 29, 2025
    Why is the green LED flashing on my Ecolab Computer Hardware?
    • T
      Tracy HallAug 30, 2025
      A flashing green LED indicates that the system is in standby mode. Press the QUIT button for 2 seconds to return to operation mode.
  • J
    joshuahessSep 4, 2025
    What to do if the pump doesn't work in conductivity mode on my Ecolab Ecodos-PCB Computer Hardware?
    • W
      williamsmirandaSep 4, 2025
      If the pump doesn't work or the solenoid valve doesn't open in conductivity mode, it might be due to the measuring probe not being connected to the PCB, or if in 2-wire mode, the DW may be filled with DEMI-water (cond < 100µS/cm). Connect the probe to “1 ... 7” resp. “8 + 9”. If in 2-wire mode, connect a wire link between “3” and “4”. Be aware that metering starts the moment the dosing unit stands live and conductivity < setpoint.